ELECTRICAL REQUIREMENTS

Electrical Shock Hazard

Plug into a grounded 3 prong outlet. Do not remove the ground prong. Do not use an adapter

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock

Recommended Ground Method

The electrical ratings for your air conditioner are listed on the model and serial number label located on the front left side of the unit (when facing the front).

Specific electrical requirements are listed in the chart below. Follow the requirements below for the type of plug on the power supply cord.

Wiring Requirements

Power Supply Cord

 

 

115 volt (103.5 min.—126.5 max)

0-12 amps

15-amp time-delay fuse or circuit breaker

Use on single outlet circuit only

For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a 3 prong power supply cord with a grounded plug. To minimize the possibility of electrical shock, the cord must be plugged into a 3 prong outlet and grounded in accordance with all local codes and ordinances. If a 3 prong outlet is not available, it is the cus- tomer’s responsibility to have a properly grounded 3 prong outlet installed by a qualified electrician.

It is the customer’s responsibility:

Copies of the standards listed may be obtained from:

• To contact a qualified electrician

National Fire Protection Association

• To assure that the electrical installation is adequate

One Batterymarch Park

Quincy, Massachusetts 02269

and in conformance with the National Electrical Code,

ANSI/NFPA 70 - latest edition, and all local codes and

 

ordinances.

 

 

 

LCDI Power Cord and Plug

 

This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord that is required by UL. This power supply cord contains state-of-the-art electronics that sense leakage current. If the cord is damaged and leakage occurs, power will be disconnected from the unit.

The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test the plug:

1.Plug power cord into a grounded 3 prong outlet

2.Press RESET (on some units a green light will turn on).

3.Press the TEST Button, the circuit should trip and cut all power to the air conditioner (on some units a green light may turn off.

4.Press the RESET button for use. You will hear a click and the A/C is not ready for use.

NOTES:

The RESET button must be engaged for proper use.

The power supply cord must be replaced if it fails to trip when the TEST button is pressed and the unit fails to reset.

Do not use the power supply cord as an ON/OFF switch. The power supply cord is designed as a protection device.

A damaged power supply cord must be replaced with a new power supply cord from Soleus Air Powered by Gree.

The power supply cord contains new user serviceable parts. Opening the tamper-resistant case voids all warranty and per- formance claims.

NOTE: Your units power cord and plug may differ from the one shown.

3

Page 3
Image 3
Soleus Air SG-WAC-10ESE-F, SG-WAC-12ESE-F manual Electrical Requirements, Recommended Ground Method

SG-WAC-10ESE-F, SG-WAC-12ESE-F specifications

The Soleus Air SG-WAC-12ESE-F and SG-WAC-10ESE-F are two standout window air conditioning units designed to provide effective cooling and comfort in residential spaces. Known for their innovative features and advanced technologies, these models cater to diverse cooling needs while maintaining energy efficiency.

One of the primary features of both models is their powerful cooling capacity. The SG-WAC-12ESE-F offers a cooling capacity of 12,000 BTUs, making it ideal for larger rooms up to 450 square feet. In contrast, the SG-WAC-10ESE-F provides a slightly lower capacity of 10,000 BTUs, suitable for spaces around 350 square feet. This range of capacities ensures efficient cooling solutions for various room sizes.

Energy efficiency is a key characteristic of these units. Both the SG-WAC-12ESE-F and SG-WAC-10ESE-F come with high Energy Efficiency Ratios (EER), which helps customers save on electricity bills while maintaining a comfortable indoor environment. They are designed with eco-friendly refrigerants, further decreasing their environmental impact.

Another highlight of these models is their multi-functionality. They feature not only cooling modes but also fan-only and dehumidification modes. This versatility allows users to select the best operation mode based on their needs, particularly during milder weather conditions when full cooling isn't necessary.

The units are equipped with user-friendly digital controls and a remote that allows for convenience and ease of use. The programmable timer feature enables customers to pre-set operation schedules, ensuring that the room is at the desired temperature when they arrive home. Additionally, the units come with adjustable air louvers that direct airflow where it is needed most, improving cooling efficiency.

Noise levels are also a significant consideration, and these models have been engineered to operate quietly. Their reduced operational noise ensures minimal disturbance, making them suitable for bedrooms, offices, or other quiet spaces.

Installation of the Soleus Air SG-WAC-12ESE-F and SG-WAC-10ESE-F is simplified with a user-friendly design that facilitates easy mounting in standard windows. Their durable construction and sleek appearance also blend seamlessly with various home aesthetics.

In summary, the Soleus Air SG-WAC-12ESE-F and SG-WAC-10ESE-F are efficient, powerful, and versatile window air conditioning units that meet the cooling needs of different room sizes. With energy-saving features, user-friendly controls, and quiet operation, they are excellent choices for anyone looking to enhance indoor comfort.