ELECTRICAL REQUIREMENTS

Electrical Shock Hazard

Plug into a grounded 3 prong outlet. Do not remove the ground prong. Do not use an adapter

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock

The electrical ratings for your air conditioner are listed on the model and serial number label located on the front left side of the unit (when facing the front).

Specific electrical requirements are listed in the chart below. Follow the requirements below for the type of plug on the power supply cord.

Power Supply Cord

NEMA 6-20P

Recommended Ground Method

For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a 3 prong power supply cord with a grounded plug. To minimize the possibility of electrical shock, the cord must be plugged into a 3 prong outlet and grounded in accordance with all local codes and ordinances. If a 3 prong outlet is not available, it is the cus- tomer’s responsibility to have a properly grounded 3 prong outlet installed by a qualified electrician.

It is the customer’s responsibility:

Copies of the standards listed may be obtained from:

• To contact a qualified electrician

National Fire Protection Association

• To assure that the electrical installation is adequate

One Batterymarch Park

Quincy, Massachusetts 02269

and in conformance with the National Electrical Code,

ANSI/NFPA 70 - latest edition, and all local codes and

 

ordinances.

 

 

 

LCDI Power Cord and Plug

 

This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord that is required by UL. This power supply cord contains state-of-the-art electronics that sense leakage current. If the cord is damaged and leakage occurs, power will be disconnected from the unit.

The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test the plug:

1.Plug power cord into a grounded 3 prong outlet

2.Press RESET (on some units a green light will turn on).

3.Press the TEST Button, the circuit should trip and cut all power to the air conditioner (on some units a green light may turn off.

4.Press the RESET button for use. You will hear a click and the A/C is not ready for use.

NOTES:

The RESET (A) button must be engaged for proper use.

The power supply cord must be replaced if it fails to trip when the TEST button (B) is pressed and the unit fails to reset.

Do not use the power supply cord as an ON/OFF switch. The power supply cord is designed as a protection device.

A damaged power supply cord must be replaced with a new power supply cord from Soleus Air Powered by Gree.

The power supply cord contains new user serviceable parts. Open- ing the tamper-resistant case voids all warranty and performance claims.

NOTE: Your units power cord and plug may differ from the one shown.

3

Page 3
Image 3
Soleus Air SG-WAC-12HCE operating instructions Electrical Requirements, Recommended Ground Method, Lcdi Power Cord and Plug

SG-WAC-12HCE specifications

The Soleus Air SG-WAC-12HCE is a powerful and efficient window air conditioning unit designed to provide a comfortable indoor climate even during the hottest summer months. With its sleek design and effective cooling capabilities, this air conditioner has gained popularity among consumers looking for reliability and performance.

One of the standout features of the Soleus Air SG-WAC-12HCE is its 12,000 BTU cooling capacity, making it suitable for medium to large rooms up to 550 square feet. This powerful cooling performance is complemented by a dehumidification mode, which can remove up to 3.5 pints of moisture per hour. This combination ensures that not only is the air cooled down but also makes it less humid, providing a more comfortable living environment.

Energy efficiency is another primary characteristic of the SG-WAC-12HCE. With an Energy Efficiency Ratio (EER) of 12.0, this unit is designed to reduce energy consumption while delivering optimal cooling performance. This feature is essential for those looking to keep energy bills in check while maintaining a pleasant indoor atmosphere. The unit is also ENERGY STAR certified, demonstrating its commitment to minimal environmental impact.

The Soleus Air SG-WAC-12HCE comes equipped with an array of user-friendly controls. It features an intuitive remote control, allowing users to adjust the temperature settings, fan speeds, and modes from the comfort of their couch or bed. The electronic controls include a digital display, making it easier to monitor and set the desired cooling levels accurately.

Additionally, this air conditioner offers three cooling speeds and three fan-only speeds, giving users the flexibility to customize their comfort level based on personal preferences and varying weather conditions. The unit also features a programmable 24-hour timer, which allows for scheduled operation, ensuring the air conditioner only runs when needed.

Installation of the SG-WAC-12HCE is straightforward, thanks to the included window installation kit, which makes it compatible with most standard window sizes. Overall, the Soleus Air SG-WAC-12HCE is a feature-rich window air conditioning unit that excels in cooling efficiency, user convenience, and versatility, making it an exceptional choice for consumers looking to stay cool and comfortable.