Soleus Air SG-WAC-25HCE manual Assembly & Installation - Thru-The-Wallcont

Models: SG-WAC-25HCE

1 20
Download 20 pages 25.33 Kb
Page 12
Image 12
ASSEMBLY & INSTALLATION - THRU-THE-WALL (CONT.)

ASSEMBLY & INSTALLATION - THRU-THE-WALL (CONT.)

Carefully measure and cut an opening with the following dimensions depending on your model (FIG. 1 & 2).

WIDTH “X” = inside model plus twice the thickness of the framing material used.

HEIGHT “Y” = inside model height plus twice the thickness of framing material used.

Model

SG-WAC-25HCE

 

 

Inside Frame Height

18 7/8” (47.9 cm)

 

 

Inside Frame Width

26 3/4” (67.9 cm)

 

 

NOTE: If wall thickness is 8-12” or more, add aluminum flashing over the bottom of the frame opening to assure water is unable to enter the area between the inner and outer wall.

FIG. 2

4.Build a wooden frame with the INSIDE dimensions of your model listed above (Measure twice). The frame depth should be the same as the wall thickness. Fill in extra space from the opening to the studs with wood spacers as shown below.

5.Nail the spacers to the studs. They should be flush with the dry wall.

Prepare and Install the Cabinet

1.Slide the chassis from the cabinet. Refer back to the REMOVE CHASSIS instructions and FIG. 1-6 in the

WINDOW MOUNTING SECTION.

2.Place the cabinet into the opening with the bottom rail resting firmly on the bottom board of the wood frame.

3.Position the cabinet so it is tilted properly for water re- moval as seen below.

FIG. 1

4.Secure the bottom rail to the wood frame with two large 1” (2.5 cm) long wood screws as shown below.

FIG. 2

12

Page 12
Image 12
Soleus Air SG-WAC-25HCE manual Assembly & Installation - Thru-The-Wallcont, Prepare and Install the Cabinet