1-3(E)
AMS-100
1-4. Rack Mounting
The AMS-100 can be mounted in a 19-inch standard rack.
n
.If the AMS-100 or the peripheral equipment is mounted
in a 19-inch standard rack, it is recommended to install a
ventilation fan to prevent a temperature rise in the rack.
Make sure that all the units in the rack should be operat-
ed within the temperature range of 5dC to 40dC.
.Connect the enough long cables on the rear panel,
considering that the AMS-100 is pulled out.
.Be sure to fix the rack to the floor with bolts.
This will prevent the rack from falling when the unit is
pulled out from the rack.
Required parts
.Rack mount rail (RMM-30)
Rail with bracket : 2 pcs.
Screw (B5x8) : 4 pcs.
Screw (PWH4x10) : 2 pcs.
Plate nut : 2 pcs.
.Screw for inner rail (B4x8) : 6 pcs.
.Screw for rack mounting (RK5x16) : 4 pcs.
.Washer for rack mounting : 4 pcs.
(Sony part number : 2-297-913-00)
c
Be sure to use the RMM-30 rack mount rail.
If a rack mount rail other than the RMM-30 is used, the
AMS-100 may be dropped by insufficient strength of the
rack mount rail. This may cause a injury.
Procedures
1. Turn off the power.
2. Attach the inner rails to the unit using the six screws
(B4x8) supplied with the RMM-30.
3. Temporarily fix the front and rear brackets to the rack
by running in but not tightening the four screws
(B5x8) and two screws (PWH4x10) supplied with the
RMM-30.
_To be continued on the next page._
B 4x8
B 4x8
Inner rail
Inner rail
1-4. Rack Mounting
PWH 4x10
Plate nut
15.9
15.9
12.7
15.9
15.9
12.7
Rack
B 5x8
Front bracket
Rear bracket
31.75