Switches 3 to 5 (Camera address selectors) Set the address of the camera.

Normally set to "0". With this setting, addresses are assigned to the cameras automatically in the connected order by pressing the POWER button while holding down the RESET button on the RM- BR300 Remote Control Unit.

You can assign the camera address "1" to "7" manually by setting these selectors as follows:

Camera

0

1

2

3

4

5

6

7

address

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch 3 OFF

ON

OFF ON

OFF ON

OFF ON

 

 

 

 

 

 

 

 

Switch 4

OFF

OFF

ON

ON

OFF OFF

ON

ON

 

 

 

 

 

 

 

 

 

Switch 5

OFF

OFF

OFF

OFF

ON

ON

ON

ON

 

 

 

 

 

 

 

 

 

Note

Switch 6 is not used.

KVISCA RS-232C IN connector

Connect to the RM-BR300 Remote Control Unit (not supplied). When you connect multiple cameras, connect it to the VISCA RS-232C OUT connector of the previous camera in the daisy chain connection.

LVISCA RS-232C OUT connector

When you connect multiple cameras, connect it to the VISCA RS-232C IN connector of the next camera in the daisy chain connection.

MCAMERA connector

Connect to the optical connector of the BRBK-303 Optical Multiplex Card installed in the BRC-300/ 300P camera using the CCFC-M100 Optical Fiber Cable.

A dustproof cap is attached at the factory.

BRBK-301 Analog RGB Component Card (not supplied)

1

RGB/SYNC

ARGB/SYNC connector

Supplies various analog signals such as composite video, S video, component video and RGB signals. The output signal can be selected with the ANALOG OUT menu of the camera.

BRBK-302 SDI Card (not supplied)

1

ASDI connector

Supplies a signal conforming to SMPTE259M serial digital interface standards.

BRBK-303 Optical Multiplex Card (not supplied)

1

AOptical connector

Performs the optical digital multiplex transmission of video, external sync and control signals.