Maintenance information and precautions

Caution

Do not remove any other screws. You may remove only the screw to remove the eyecup.

Notes

Do not drop or bend the eyecup shaft.

Be careful when handling the eyecup.

Charging the built-in rechargeable battery

Your camcorder has a built-in rechargeable battery so that the date, time and other settings are retained even when the POWER switch is turned off. The built-in rechargeable battery is always charged as long as you are using your camcorder. The battery, however, will get discharged gradually if you do not use your camcorder. It will be completely discharged in about three months if you do not use your camcorder at all. Even if the built-in rechargeable battery is not charged, it will not affect the camcorder operation. To retain the date and time, etc., charge the battery if the battery is discharged.

Charging the built-in rechargeable battery

Connect your camcorder to the house current using the AC adaptor supplied with your camcorder, and leave your camcorder with the POWER switch turned off for more than 24 hours.

Or install the fully charged battery pack in your camcorder, and leave your camcorder with the POWER switch set to OFF (CHARGE) for more than 24 hours.

Adjusting the LCD screen (CALIBRATION)

The buttons on the touch panel may not work correctly. If this happens, follow the procedure below.

(1) Set the POWER switch to OFF (CHARGE).

(2) Eject the tape from your camcorder, then disconnect any connecting cable from your camcorder.

(3) Set the POWER switch to VCR while pressing DISPLAY/TOUCH PANEL on your camcorder, then keep pressing DISPLAY/TOUCH PANEL for about five seconds.

(4) Follow the procedure below using an object such as the corner of a “Memory

Stick.”

 

1 Touch

at the upper left corner.

2 Touch

at the lower right corner.

3 Touch

in the middle of the screen.

Information Additional

CALIBRATE

CALIBRATE

CALIBRATE

END

Note

If you do not press the right spot, always returns to the position at the upper left corner. In this case, start from step 4 again.