CEA SPECIFICATIONS
CO3002
Power Output: 60 Watts RMS x 2 at 4 ohms and < 1% THD+N
Signal to Noise Ratio:
Additional Power: 80 Watts RMS x 2 at 2 ohm and < 1% THD+N
CO6002
Power Output: 100 Watts RMS x 2 at 4 ohms and < 1% THD+N
Signal to Noise Ratio:
Additional Power: 155 Watts RMS x 2 at 2 ohm and < 1% THD+N
HIGH LEVEL HARNESSES
Do not connect the high level input connections to power, signal, or chassis ground as damage to the
HIGH LEVEL CONNECTIONS
WIRE COLOR | INPUT CONNECTION |
|
|
Black | Ground |
|
|
White/Black | - Left channel |
|
|
White | + Left channel |
|
|
Gray/Black | - Right channel |
|
|
Gray | + Right channel |
|
|
AMPLIFIER SETTINGS
Signal Input and Output Configurations
The input section of the amplifier consists of a phase switch that sets the output configuration, gain controls, and RCA inputs. The input section makes it easy to adapt this amplifier to most system configurations.
Input Gain
The Orion Cobalt CO3002 and CO6002 amplifiers have level adjustments to allow for easy inte- gration with any source unit. The input sensitivity can be adjusted from 175mV to 8V. Refer to Testing the System and Adjusting the Sound of the System sections of this guide for detailed instructions on setting the gain.
© 2008 directed | 5 |