1-18 DVS-9000/9000SF
1-8. Checks on Completion of Installation
A side/Component side
2. MIX-46 board (DVS-9000/9000SF/BKDS-9210)
TP302
D308
TP301
D304 TP101
D104
TP102
D108 TP201
D204
E321
1
2
3
4
5
6
7
8
9
10
11
12
13
AB C DE FG H J KL MNP R
S301
S2301
SL3
CN3301
D3004
D3005
D3006
D3001
D3002
D3003
CN2401
E310
E309
E308 E306
E302 E301
TP2402
TP2403
TP2401
TP2404
SL2
SL1
<LED>
D104, D108, D204 (A-4) : ++
++
+1.8 V-1 to 3
+1.8 V-1 to 3 power supply status indication.
Lit when the +1.8 V-1 to 3 power are supplied.
D304 (A-3) : ++
++
+3.3 V
+3.3 V power supply status indication.
Lit when the +3.3 V power is supplied.
D308 (A-3) : ++
++
+12 V
+12 V power supply status indication.
Lit when the +12 V power is supplied.
If this LED does not light, the fuse may have blown.
D3001 (A-10): DLL UNLOCK status LED
Indicates lock/unlock of the DLL (Delay Locked Loop) in
the FPGA.
If this LED lit, the DLL can possibly be unlocked.
D3002 (A-11): PLL UNLOCK status LED
Indicates lock/unlock of the PLL (Phase Locked Loop) in
the FPGA.
If this LED lit, the PLL can possibly be unlocked.
D3003 (A-11): CONFIG. ERROR status LED
Indicates the configuration error of the FPGA.
If this LED lit, the FPGA can possibly be working incor-
rectly.
D3004, D3005, D3006 (A-10): C2, C1 and C0 status
LED
Indicates the status of CPU on the circuit board.