2-4 BKDW-515
2-4. Error Message
2-4-1. Operation when Checksum Error of
Current Setup Data Occurs
If the power switch is turned on when the current setup
data on the control panel was destroyed for some trouble,
message CURRENT setup DATA ERROR is displayed
on the EL panel. The current setup data is automatically
reset to the factory-setting value at the same time.
2-4-2. Correction when Checksum Error of
VTR Bank Data Occurs
If the power switch is turned on when the VTR bank data
on the control panel was destroyed for some trouble,
message VTR bank CHECKSUM ERROR is displayed
on the EL panel. Confirm the type of the bank data to have
been destroyed in a VTR BANK menu or MEMORY
CARD menu and copy normal bank data. The title of the
destroyed bank data is displayed as DAMAGED.
2-4-3. Correction when Checksum Error of
Memory Card Data Occurs
If the memory card is inserted into the slot on the control
panel when the data of a memory card was destroyed for
some trouble, message Data DAMAGED is displayed on
the EL panel. Confirm the destroyed bank data or cue set
data and copy normal data. The title of the destroyed data
is displayed as DAMAGED (for only WRITE PRO-
TECT OFF in a memory card).
2-4. Error Message