DXC-990/990P
3-205-543-11 (1)
D:\Nouhin\DXC990UC\320554311DXC990UC\02GB-
DXC990UC\04ADJ.fm
masterpage:Left
19 GB
GENERAL Menu
Adjusting and Setting with Menus
LEVEL
Adjusts the level within the range from 127
to +127. Adjust while watching the screen so
that the color is eliminated.
+: Green at the top and magenta at the
bottom will be eliminated.
–: Magenta at the top and green at the
bottom will be eliminated.
Sets when you use a slave unit connected to
the TRIG IN connector and synchronize the
camera with a stroboscope.
OFF
Select when you do not connect a slave unit.
ON
Select when you connect a slave unit.
POLARITY
Sets to the same polarity as the input pulse
signal.
: Falling edge
: Rising edge
Reverses the output image to negative/
positive.
OFF
Outputs the image normally.
ON
Outputs the image reversed to negative/
positive.
When using the camera in a 50 Hz lighting
area (DXC-990) or in a 60 Hz lighting area
(DXC-990P), you can obtain images with
less flicker under fluorescent light even
when SH UTT ER is se t to CC D I RI S or OF F.
Set this item to OFF when you want to set
NEGA to ON.
OFF
Disables the FLICKER CANCELLER
function.
ON
Reduces flicker under fluorescent light.
TRIGGERNEGAFLICKER CANCELLER