Basic Functions

ALARM Setting Command List

Command Set

Command

Command Packet

Comments

CAM _ Alarm

On

 

8x 01 04 6B 02 FF

Alarm start

 

 

 

 

 

 

Off

 

8x 01 04 6B 03 FF

Alarm stop

 

 

 

 

 

 

Set Mode

8x 01 04 6C pp FF

Mode Setting

 

 

 

 

*Select one from 13 modes

 

 

 

 

 

 

Set Day Night Level

8x 01 04 6D 0p 0p 0p

ppp: Day distinction AE level

 

 

 

0q 0q 0q FF

qqq: Night distinction AE level.

 

 

 

 

 

 

 

 

 

 

 

 

 

90 07 04 6B 01 FF

High signal output

 

 

 

 

(Low t High edge)

 

 

 

 

 

 

 

 

90 07 04 6B 00 FF

Low signal output

 

 

 

 

(High t Low edge)

 

 

 

 

 

 

 

 

 

 

VISCA Mode Code (pp)

Details of Mode

 

 

 

 

 

00

 

Set the internal focus position. When focus movement is detected, the detect signal is High. When focus goes

 

 

back to the previous position, the detect signal is Low.

 

 

 

 

01

 

Set a fixed period of time. When focus does not move during the time, the focus position is memorized as a

 

 

rest position and the detect signal is Low.

 

 

 

When focus moves, the detect signal is High. Afterwards when focus does not move for the fixed period of

 

 

time, the focus position is memorized and the detect signal becomes Low.

 

 

 

02

 

Set the internal AE Level. When AE movement is detected, the detect signal is High. When AE Level goes

 

 

back to the previous level, the detect signal is Low.

 

 

 

 

03

 

Set a fixed period of time. When AE Level does not change during this time, the AE value is memorized as a

 

 

rest value and the detect signal is Low.

 

 

 

When AE value changes, the detect signal is High.

 

 

 

Afterwards when AE value does not change for the fixed period of time, the AE value is memorized and the

 

 

detect signal becomes Low.

 

 

 

 

 

 

 

04

 

mode “00” and mode “02”

 

 

 

 

 

 

 

05

 

mode “00” and mode “03”

 

 

 

 

 

 

 

06

 

mode “01” and mode “02”

 

 

 

 

 

 

 

07

 

mode “01” and mode “03”

 

 

 

 

 

 

 

08

 

mode “00” or mode “02”

 

 

 

 

 

 

 

09

 

mode “00” or mode “03”

 

 

 

 

 

 

 

0A

 

mode “01” or mode “02”

 

 

 

 

 

 

 

0B

 

mode “01” or mode “03”

 

 

 

 

 

 

 

0C

 

Day-Night Mode

 

 

 

 

 

 

 

ALARM Inquiry Command List

Inquiry Command

Command Packet

Inquiry Packet

Comments

CAM _ Alarm Inq

8x 09 04

6B FF

y0

50

02 FF

On

 

 

 

 

 

 

 

 

 

 

 

 

y0

50

03 FF

Off

 

 

 

 

 

 

CAM _ Alarm Mode Inq

8x 09 04

6C FF

y0

50 pp FF

pp: Alarm Mode

 

 

 

 

 

 

 

 

 

CAM_AlarmDayNightLevel Inq

8x

09 04

6D FF

y0

50

0p

0p 0p

ppp: Day setting AE Level

 

 

 

 

0q

0q

0q

0r 0r 0r FF

qqq; Night setting AE Level

 

 

 

 

 

 

 

 

rrr: Now AE Level

 

 

 

 

 

 

 

 

 

CAM_AlarmDetLevelInq

8x

09 04

6E FF

y0

50

01

FF

Detect Level is High.

 

 

 

 

y0

50

00

FF

Detect Level is Low.

 

 

 

 

 

 

 

 

 

19