7
FWD-42PV1/42PV1P/42PV1A
IP Address
Syntax Header Category Function Data1 Data2 Data3 Data4 Data5 Check Sum
Control 0x8C 0x00 0x42 0x05 Address Address 1 Address 2 Address 3 0xXX
00x00-0xFF 0x00-0xFF 0x00-0xFF 0x00-0xFF
Answer Header Answer Check Sum
Control 0x70 0x00 0x70 Completed
0x70 0x03 0x73 Command Canceled
IP Address ex)
192.128.14.1 192 (0xC0) Address 0
128 (0x80) Address 1
14 (0x0E) Address 2
1 (0x01) Address 3
* IP Address command can be carried out even in the standby state.
Code Table(1-a)
[a]Function [b]Range/Switch code Command
Control Enquiry Standby Power On
0x42 IP Address Yes Yes Enable Enable
0x45 Control Mode 0x00Main+Remocon Yes Yes Disable Enable
0x01 Main
0x02 Remocon
0x03 Both Disable
0x46 On Off Timer Mode 0x00 Every Day Yes Yes Enable Enable
0x01 Day Of Week
0x47 On Timer Enable bit0 Sunday 1: Enable, 0: Disable Yes Yes Enable Enable
bit1 Monday 1: Enable, 0: Disable
bit2 Tuesday 1: Enable, 0: Disable
bit3 Wednesday 1: Enable, 0: Disable
bit4 Thursday 1: Enable, 0: Disable
bit5 Friday 1: Enable, 0: Disable
bit6 Saturday 1: Enable, 0: Disable
bit7 Every day 1: Enable, 0: Disable
0x48 Off Timer Enable bit0 Sunday 1: Enable, 0: Disable Yes Yes Enable Enable
bit1 Monday 1: Enable, 0: Disable
bit2 Tuesday 1: Enable, 0: Disable
bit3 Wednesday 1: Enable, 0: Disable
bit4 Thursday 1: Enable, 0: Disable
bit5 Friday 1: Enable, 0: Disable
bit6 Saturday 1: Enable, 0: Disable
bit7 Every day 1: Enable, 0: Disable