CAMERA SELECT (DAH+92H)

Directly selects the camera to be monitored. Parameter bytes to specify the output port (A or B) and the camera number and the ENTER command (40H) must follow.

By setting the camera number to A (3AH) for output port B, the same signal as that from port A can be output from both ports.

Example: To select camera 16 for output port B:

 

EXP-3

 

 

CMD

 

 

 

B

1

6

 

 

ENTER

RxD

DAH

 

 

 

92H

 

 

 

3BH

 

 

 

31H

 

 

 

36H

 

 

 

40H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TxD

0AH

 

 

0AH

 

 

0AH

 

 

0AH

 

 

0AH

 

 

 

0AH

 

 

 

 

 

ACK

 

ACK

 

ACK

 

ACK

 

ACK

 

 

 

ACK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T/D PRESET (DAH+93H)

Sets the built-in clock.

Parameter bytes to specify the year, month, day, hour (24H mode), minute and second in this sequence and the ENTER command (40H) must follow.

Example: To set January 1, 1998, 3:10, and 58 seconds p.m.:

 

EXP-3

 

 

CMD

 

 

 

9

 

 

 

8

 

 

 

0

ENTER

RxD

DAH

 

 

 

93H

 

 

 

39H

 

 

 

38H

 

 

 

30H

 

40H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TxD

0AH

 

 

0AH

 

 

 

0AH

 

 

 

0AH

 

 

 

 

 

0AH

 

 

 

 

 

ACK

 

ACK

 

 

ACK

 

 

ACK

 

 

 

 

ACK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALARM SET (DAH+94H)

Sets the VTR to Alarm mode.

Parameter bytes to control the alarm may follow. The parameters are of the same format as those of the return data for ALARM SENSE.

 

bit 7

bit 6

bit 5

bit 4

bit 3

bit 2

bit 1

bit 0

byte 1

1

0

0

0

0

0

ALL CAMERAS

byte 2

CAMERA4

CAMERA3

CAMERA2

CAMERA1

byte 3

CAMERA8

CAMERA7

CAMERA6

CAMERA5

byte 4

CAMERA12

CAMERA11

CAMERA10

CAMERA9

byte 5

CAMERA16

CAMERA15

CAMERA14

CAMERA13

 

 

 

 

 

 

 

 

 

 

EXP-3

 

 

CMD

 

 

DATA

 

DATA

DATA

DATA

RxD

DAH

 

 

 

94H

 

 

 

80H

 

xxH

 

 

 

xxH

 

 

 

xxH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TxD

0AH

 

 

0AH

 

 

 

 

0AH

 

 

 

0AH

 

 

 

0AH

 

 

 

 

 

ACK

 

ACK

 

 

 

ACK

 

 

 

ACK

 

 

 

ACK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

First byte

Bits 1 and 0: Specify the alarm input common to all cameras.

00:Cancel alarm input

01:Specify the alarm input

11:No change

Second to fifth bytes

Each two bits specifies the alarm input of the corresponding camera.

00:Cancel alarm input

01:Specify the alarm input

11:No change

REC MODE (DAH+98H)

Specifies the Recording mode.

 

bit 7

bit 6

bit 5

bit 4

bit 3

bit 2

bit 1

bit 0

byte 1

1

0

0

0

0

NORMAL REC MODE

byte 2

0

TIMER

REPEAT

CONTINU-

0

ALARM

0

0

REC

REC

OUS REC

REC

 

 

 

 

 

 

 

 

 

Example: To specify Recording mode 1 for normal recording and activate Repeat recording:

EXP-3 CMD CMD CMD

RxD DAH 98H 81H 20H

TxD

0AH

 

0AH

 

0AH

 

0AH

 

 

ACK

 

ACK

 

ACK

 

ACK

 

First byte

Bits 2 to 0: Specify the recording mode for normal recording.

Second byte

Bit 6: Activates/deactivates Timer recording.

0:Inactive

1:Active

Bit 5: Activates/deactivates Repeat recording.

0:Inactive

1:Active

Bit 4: Activates/deactivates Continuous recording.

0:Inactive

1:Active

Bit 2: Activates/deactivates Alarm recording.

0:Inactive

1:Active

7