Frequency/Repetition

 

Alkaline

Lithium

Nickel hydride

 

 

 

(1550 mAh)

Frequency (sec)

0.2 - 6

0.2 - 6

0.2 - 5

Repetition (times)

200 - 4000

500 - 10000

150 - 3000

Repetition is the approximate number of times that are possible before a new battery is completely dead.

Flash coverage

 

 

Flash Coverage Setting (mm)

 

 

 

 

 

 

 

 

Flash coverage

17*

24

28

35

50

85

Top-bottom (° )

115

60

53

45

34

23

Left-right (° )

125

78

70

60

46

31

 

 

 

 

 

 

 

* When the wide panel is attached

Continuous

40 flashes at 5 flashes per second

flash performance

(Normal flash, GN 6, 85 mm, nickel-metal

 

hydride battery)

AF illuminator

Autoflash at low contrast and low brightness

 

Operating range (with a 50 mm lens attached to α100)

 

Central area: 0.5 m to 6 m

 

Pripheral areas : 0.5 m to 3 m

Flash control

Flash control using pre-flash, TTL direct metering

Dimension

W 68 ⋅ H 122 ⋅ D 89 mm

(Approx.)

(2 3/4 ⋅ 4 7/8 ⋅ 3 5/8 inches)

Mass (Approx.)

260 g (9.2 oz)

Included items

Flash (1), Mini-stand (1), Case (1), Wide panel (1),

 

Set of printed documentation

Functions in these operating instructions depend on testing conditions at our firm.

Design and specifications are subject to change without notice.

42