5.The display changes a shown below each time the jog dial (down) is turned or the [DISPLAY] key on the remote commander is pressed.
• Address & Adjusted Value Display
Remote commander LCD display
011C 6 8 S 0 1
|
|
|
|
|
|
|
address |
|
| adjusted value | |||
|
|
item number
• Jitter Value & Adjusted Value Display
Remote commander LCD display
011O F F J 0 1
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| jitter |
| value |
|
|
|
| adjusted value | ||
|
|
|
|
|
|
|
|
| |||||
| |||||||||||||
item number |
|
|
|
|
| ||||||||
|
|
|
|
• Block Error Value & Adjusted Value Display
Remote commander LCD display
0110 6 3 B 0 1
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| block error |
|
|
| adjusted value | |||
item number value |
|
|
| ||||||||
|
|
|
|
• ADIP Error Value & Adjusted Value Display
Remote commander LCD display
0110 5 9 A 0 1
|
|
|
|
|
|
|
|
|
|
|
| adjusted value |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| ADIP error |
|
|
|
| ||||
|
|
|
| |||||||||
item | number value |
|
|
|
|
| ||||||
|
|
|
|
• Focus Drive Value & Adjusted Value Display
Remote commander LCD display
0110 1 5 F 0 1
|
|
|
|
|
|
|
Focus drive |
|
| adjusted value | |||
|
|
item number value
• Item Title Display
Remote commander LCD display
| 011 L r e f P w | 0 1 | ||||||||
|
|
|
|
|
|
|
|
| ||
|
|
|
| item |
| title |
|
|
| adjusted value |
| ||||||||||
|
|
|
|
|
|
| ||||
item | number |
|
|
|
|
However in the power mode (item number 700’s), only the item is displayed.
6.Quit the manual mode, and press the x/CHG key to return to the test mode (display check mode).
Overall Adjustment Mode
Mode to adjust the servo automatically in all items.
Normally, automatic adjustment is executed in this mode at the repair.
For further information, refer to “SECTION 5 ELECTRICAL ADJUSTMENTS” (see page 19).
This set uses the
By checking this history in the test mode, you can analyze a fault and determine its location.
Total recording time is recorded as a guideline of how long the optical pickup has been used, and by comparing it with the total recording time at the time when an error occurred in the self- diagnosis result display mode, you can determine when the error occurred.
Clear both
•
1.Set the test mode (see page 13).
2.In the display check mode, turn the jog dial (down) or press the [DISPLAY] key on the remote commander activates the self- diagnosis result display mode where the LCD display as shown below.
Remote commander LCD display
0XX 1 0 0 0 0
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Total recording time | ||
|
|
| history code |
| |||||||
|
|
| |||||||||
|
|
|
|
|
|
|
|
| when error occurred | ||
error display code | |||||||||||
|
|
|
3.Then, each time the > key is pressed, LCD display descends by one as shown below. Also, the LCD display ascends by one when the . key is pressed.
| 1 | |
0XX 1 |
| |
|
| |
* * * * | ||
0XX N |
|
|
|
| |
* * * * |
0XX N 1 * * * *
0XX N 2 * * * *
0XX R _ * * * *
1
XX: Error code
** * * : Total recording time
If the jog dial (down) is turned or the [DISPLAY] key on remote commander is pressed with this display, the LCD switches to the simple display mode.
4.Quit the