2. NV adjusted values modifying procedure
1)Select manual mode of the test mode, and set item number 336 (see page 14).
Remote commander LCD display
336 AbcdGn **
**: Adjusted value
2)Adjust with the [VOLUME +] key (adjusted value up) or [VOL- UME
3)Press the X key to write the adjusted value.
4)Select manual mode of the test mode, and set item number 149 (see page 14).
5)Press the > key to set item number 151.
Remote commander LCD display
151 Dfct 1 **
**: Adjusted value
6)Adjust with the [VOLUME +] key (adjusted value up) or [VOL- UME
7)Press the X key to write the adjusted value.
8)Select manual mode of the test mode, and set item number 861 (see page 14).
Remote commander LCD display
861 V1 num **
**: Adjusted value
9)Adjust with the [VOLUME +] key (adjusted value up) or [VOL- UME
becomes 79.
10)Press the X key to write the adjusted value.
11)Select manual mode of the test mode, and set item number 862 (see page 14).
Remote commander LCD display
862 V1 dat **
**: Adjusted value
12)Adjust with the [VOLUME +] key (adjusted value up) or [VOL- UME
13)Press the X key to write the adjusted value.
14)Select manual mode of the test mode, and set item number 863 (see page 14).
Remote commander LCD display
863 V2 num **
**: Adjusted value
15)Adjust with the [VOLUME +] key (adjusted value up) or [VOL- UME
16)Press the X key to write the adjusted value.
17)Select manual mode of the test mode, and set item number 864 (see page 14).
Remote commander LCD display
864 V3 dat **
**: Adjusted value
18)Adjust with the [VOLUME +] key (adjusted value up) or [VOL- UME
19)Press the X key to write the adjusted value.
20)Select manual mode of the test mode, and set item number 865 (see page 14).
Remote commander LCD display
865 V3 num **
**: Adjusted value
21)Adjust with the [VOLUME +] key (adjusted value up) or [VOL- UME
22)Press the X key to write the adjusted value.
23)Select manual mode of the test mode, and set item number 866 (see page 14).
Remote commander LCD display
866 V3 dat **
**: Adjusted value
24)Adjust with the [VOLUME +] key (adjusted value up) or [VOL- UME
25)Press the X key key to write the adjusted value.
26)Select manual mode of the test mode, and set item number 867 (see page 14).
Remote commander LCD display
867 V4 num **
**: Adjusted value
27)Adjust with the [VOLUME +] key (adjusted value up) or [VOL- UME
28)Press the X key to write the adjusted value.
29)Select manual mode of the test mode, and set item number 868 (see page 14).
Remote commander LCD display
868 V4 dat **
**: Adjusted value
30)Adjust with the [VOLUME +] key (adjusted value up) or [VOL- UME
31)Press the X key to write the adjusted value.
32)Select manual mode of the test mode, and set item number 871 (see page 14).
Remote commander LCD display
871 V5 num **
**: Adjusted value
33)Adjust with the [VOLUME +] key (adjusted value up) or [VOL- UME
34)Press the X key to write the adjusted value.
35)Select manual mode of the test mode, and set item number 872 (see page 14).
Remote commander LCD display
872 V5 dat **
**: Adjusted value
36)Adjust with the [VOLUME +] key (adjusted value up) or [VOL- UME
37)Press the X key to write the adjusted value.
20