1-15
PFM-42X1/42X1N
(d) Software version enquiry
Syntax
Enquiry
Execute Judge
Header
0x83
0x89
Category
0x30
Function
0x03
Data1
0xFF
0xFF
Data2
0xFF
0xFF
Answer
Enquiry
Execute Judge
Header
0x70
0x70
Answer
0x00
0x04
Return Data Size
0x02
Return Data1
Upper 8bit
Data
Return Data2
Lower 8bit
Data
Completed
Command All Enable
Return Data1 - Data2 : 0x0000 - 0xFFFF(e) H/V frequency enquiry
Syntax
Enquiry
Execute Judge
Header
0x83
0x89
Category
0x30
Function
Code Table (4-b)
Data1
0xFF
0xFF
Data2
0xFF
0xFF
Answer
Enquiry
Execute Judge
Header
0x70
0x70
0x70
0x70
Answer
0x00
0x03
0x03
0x04
Return Data Size
0x02
Return Data1
Upper 7bit
Data
Return Data2
Lower 7bit
Data
Completed
Command Canceled
Command Disable
Command All Enable
Return Data1 - Data2 : 0x0000 - 0xFFFF H Frequency = Return Data x 10 [Hz]V Frequency = Return Data / 100 [Hz]Code table (4-b)
Function
0x04 H Frequency
0x05 V Frequency
Execute Judge ACK
Standby Setup Power
Sequence
On
Disable Disable Enable
Disable Disable Enable
(f) Sync polarity enquiry
Syntax
Enquiry
Execute Judge
Header
0x83
0x89
Category
0x30
Function
0x06
Data1
0xFF
0xFF
Data2
0xFF
0xFF
Answer
Enquiry
Execute Judge
Header
0x70
0x70
0x70
0x70
Answer
0x00
0x03
0x03
0x04
Return Data Size
0x01
Return Data1
Code Table
(4-c)
Completed
Command Canceled
Command Disable
Command All Enable