7. Answer

(a)Normal message

Answer

Header

0x70

Normal answer header

 

 

 

Category

0xXX

Code table (7-a) : Normal code

 

 

 

Code table (7-a)

 

Normal code

 

 

 

 

0x00

Completed

Normal response.

 

 

 

0x01

Limit over

The packet was received normally, but the data value was over the upper

 

 

limit.

 

 

Forcedly the monitor adjusted the data to maximum value.

 

 

 

0x02

Limit under

The packet was received normally, but the data value was under the lower

 

 

limit.

 

 

Forcedly the monitor adjusted the data to minimum value.

 

 

 

0x03

Command cancelled

The packet was received normally, but the command was cancelled because

 

 

the function was not in adjustable mode, such as a function displayed as “—

 

 

—” in user menu.

 

 

 

0x04

Command all enable

The packet was received normally.

 

 

The command function is all enable.

 

 

 

0x05

Fail

The packet was received normally, but the command was cancelled .

 

 

Please retry.

 

 

 

(b)Error message

Answer

Header

0xE0

Error answer header

 

 

 

Category

0xXX

Code table (7-b) : Error code

 

 

 

Code table (7-b)

 

Normal code

 

 

 

 

0x00

No function error

Packet header,category or function codes do not exist in this protocol.

 

 

 

0x02

Data number error

The data value in “Data num” area of received packet was different from the

 

 

function’s own data number.

 

 

 

0x06

Mode error

The monitor is already in the service mode via remote commander

 

 

operation.

 

 

(The service mode through IR remote has priority over the serial remote

 

 

command. )

 

 

 

0x07

Time out

Packet communication are interrupted by some error, and did not return to

 

 

normal communication within 2 seconds.

PFM-42X1/42X1N

1-19

Page 23
Image 23
Sony PFM-42X1N manual Answer Normal message, Error message, Normal code