Shock

Operating

No Data Loss

 

Half Sine

 

Performance

 

5 G Peak 3 ms

 

3 axes, 3 directions

 

*Interval of 10 seconds

 

 

Non-operating

No Device Damage

 

Half Sine

 

90 G Peak 3 ms

 

(30 G Peak 11 ms)

 

3 axes, 3 directions

 

*Interval of 10 seconds

 

 

Temperature and Humidity Range

Temperature

Operating

5˚C to 40˚C (T<10˚C/h) (41˚F to 104˚F (T<18˚F/h))

Non-operating (mech.)

– 40˚C to 70˚C (T<20˚C/h) (– 40˚F to 158˚F (T<36˚F/h))

 

 

Non-operating (tape)

– 40˚C to 45˚C (T<20˚C/h) (– 40˚F to 113˚F (T<36˚F/h))

 

 

Humidity

 

 

 

Operating

20 to 80% RH, non-condensing

 

Maximum wet bulb temperature = 26˚C (78.8˚F)

 

 

Non-operating (mech.)

5 to 95% RH (RH<30%/h)

 

Maximum wet bulb temperature = 45˚C (113˚F)

Non-operating (tape)

20 to 80% RH (RH<30%/h)

 

 

Air-cooling Requirement

Surrounding temperature

< 40˚C (104˚F)

 

 

Clean air flow is recommended to minimize the possibility of data loss.

Power Requirements

Voltage

Max Ripple

 

Current

 

 

 

Typical

 

Maximum

 

 

 

 

 

 

 

 

5 V +/– 5 %

100 mVp-p

1.5 A

 

2.5 A

 

 

 

 

 

12 V +/– 10 %

150 mVp-p

0.75 A

 

3.0 A

27