Sony SLV-KF295CH, SLV-KA195CH Troubleshooting, 22EN, Symptoms caused by contaminated video heads

Models: SLV-KA195CH SLV-KF295CH

1 28
Download 28 pages 58.46 Kb
Page 22
Image 22
Troubleshooting

Additional Information

Troubleshooting

If you have any questions or problems not covered below, please consult your nearest Sony service facility.

 

Symptom

Remedy

 

The u (ON/STANDBY) switch

• Connect the mains lead securely.

 

does not function.

 

 

 

 

 

The power is turned on but the

• Moisture condensation occurs. Turn the power off,

 

unit does not operate.

unplug the mains lead and leave the unit to dry for

 

 

over an hour.

Power

The VCR enters standby mode or turns off automatically.

The auto safety system is triggered to protect your tape and the unit’s mechanism when there is something

wrong with the tape or when the mechanism is overloaded. Press u to restart the unit. If the unit does not work after pressing u again, disconnect the

mains lead from the mains supply. Wait for at least 15 seconds. Then reconnect mains, and press u again. If the unit still does not work, please consult your nearest Sony service facility.

Playback

The playback picture does not

• Make sure the TV is set to the video channel. If you

appear on the TV screen.

are using a monitor, set it to video input.

 

 

The picture is not clear.

• Adjust the tracking with the $/4 TRACKING

 

NORMAL/SLOW buttons.

 

• Make sure the COLOR SYSTEM switch is set to the

 

position corresponding to the colour system which the

 

tape was recorded with.

 

• The video heads are dirty (see below). Clean the video

 

heads using the Sony V-25CL video head cleaning

 

cassette. If this cleaning cassette is not available in

 

your area, have the heads cleaned at your nearest Sony

 

service facility (a standard service charge will be

 

required). Do not use a commercially available wet-

 

type cleaning cassette, as it may damage the video

 

heads.

 

• The video heads may have to be replaced. Consult

 

your local Sony service facility for more information.

 

 

The picture rolls vertically

• Adjust the vertical hold control on the TV or monitor.

during picture search.

 

 

 

The picture has no sound.

• The tape is defective. Use a new tape.

Symptoms caused by contaminated video heads

• Normal picture

• Rough picture

• Unclear picture

• No picture (or

 

 

 

black & white

 

 

 

screen appears)

22EN

initial Symptoms caused by contaminated video heads terminal

Additional Information

SLV-KF295ME/PS/KA195ME/PS 3-858-164-11 (1)

Page 22
Image 22
Sony SLV-KF295CH manual Troubleshooting, 22EN, Symptoms caused by contaminated video heads, SLV-KF295ME/PS/KA195ME/PS