Maintenance
Replacing the Lamp
When it is time to replace the lamp, replace the lamp promptly with a new
When replacing the lamp after using the projector
Turn off the projector, then unplug the power cord. Wait for at least an hour for the lamp to cool.
Note
The lamp will still be very hot after turning off the power. Wait until the lamp has cooled completely before replacing.
1 Place a protective sheet (cloth) beneath the projector. Turn the projector over so it is upside down.
Note
Be careful not to topple over the projector after turning it over.
2 Pull out the adjuster by pressing the adjuster button and turn it outward.
3 Open the lamp cover by loosening two screws with the Philips screwdriver (supplied with the LMP- 600 Projector Lamp).
For safety reasons, do not loosen the other screws.