20 VPL-VW100
<Table 1> <Table 2> Remarks
Item Number Data
Item Upper byte Lower byte Data Upper byte Lower byte
Status Error 01h 01h No Error 00h 00h Get only
Lamp Error 00h 01h
Fan Error 00h 02h
Cover Error 00h 04h
Temp Error 00h 08h
D5V Error 00h 10h
Power Error 00h 20h
Temp Warning Error 00h 40h
NVM Data Error 00h 80h
Status Power 01h 02h Stanby 00h 00h
Start Up 00h 01h
Start Up Lamp 00h 02h
Power On 00h 03h
Cooling1 00h 04h
Cooling2 00h 05h
Saving Cooling1 00h 06h
Saving Cooling2 00h 07h
Saving Stanby 00h 08h
Control Mode 01h 05h User Mode 00h 00h
Service Mode 00h 01h
Lamp Timer 01h 13h Lamp Use Time 0000h-FFFFh *1
ROM Version 01h 1Dh MAIN ROM Version *2
SC ROM Version 01h 1Eh SC ROM Version *2
NVM Data VERSION 01h 27h NVM data VERSION *3
W/B All Save 03h 04h _00h 00h Set only
W/B Low Save 05h
W/B High Save 06h
W/B Middle Save 07h
W/B Custom1 Save 08h
W/B Custom2 Save 09h
W/B Custom3 Save 0Ah
Sircs(15 bit category) 17h Refer to Table4 _00h 00h
Set only
*4
Sircs(20 bit category) 19h Refer to Table5 _00h 00h
*1 Example) In case the lamp timer indicates 1000H, return values are [03h] upper byte and [E8h] lower byte.*2 Example) In case the software version is 1.03, return values are [01h] upper byte and [03h] lower byte.*3 Example) In case the NVM data version is 3, return values are [00] upper byte and [03] lower byte.*4 It is corresponded to single command only.