Mode Setting

 

 

 

1N mode

 

 

 

 

 

 

 

 

 

 

 

External VD interval

Partial scanning setting

 

Effective lines

BLKG interval

Frame rate

 

Tv [line]

10th digit

First digit

 

X [line]

Tb [line]

[frame/s]

 

 

 

 

 

 

 

625 (20.0 ms)

0

0

 

580 (18.6 ms)

45 (1.44 ms)

50

 

312 (9.98 ms)

2

6

 

267 (8.54 ms)

45 (1.44 ms)

100

 

208 (6.65 ms)

3

6

 

157 (5.02 ms)

51 (1.63 ms)

150

 

156 (4.99 ms)

4

0

 

101 (3.23 ms)

55 (1.76 ms)

200

 

 

 

 

 

 

 

 

 

BLKG interval Tb = 15 + n (n stands for the partial scanning setting value. When the 10th digit is 2 and the first digit is 6, n=26. The maximum value of n is 99, and the minimum value of Tb is 45. When Tb45, the BLKG interval is 45H, the constant value.

Effective lines X = Tv – Tb

2I mode

External VD interval

Partial scanning setting

Effective lines*

BLKG interval

Frame rate

Tv [line]

10th digit

First digit

X [line]

Tb [line]

[frame/s]

 

 

 

 

312.5 (10.0 ms)

0

0

287.5 (9.2 ms)

25 (0.80 ms)

100

156 (5.00 ms)

1

3

128 (4.10 ms)

28 (0.90 ms)

200

104 (3.32 ms)

1

7

72 (2.30 ms)

32 (1.02 ms)

300

78 (2.50 ms)

2

0

43 (1.38 ms)

35 (1.12 ms)

400

 

 

 

 

 

 

BLKG interval Tb = 15 + n (n stands for the partial scanning setting value. When the 10th digit is 1 and the first digit is 3, n=13. The maximum value of n is 49, and the minimum value of Tb is 25. When Tb25, the BLKG interval is 25H, the constant value.

Effective lines X = Tv – Tb

*The number of effective lines in the 2I mode indicates the number of lines output from the Video 1 and 2 connectors.

– Determine and input each value for the colored columns.

13