Mode Setting

Specifications of the Input/Output

Input Phase Specifications of the External HD/VD

100 0

EVEN,

Non Interlace

External VD

100 100

ODD

External HD

472 472

Unit: Clock 1Clk=33.898 nsec

Make sure that the external HD/VD phases against the standard central phase are as shown in the figure above. Invalid signal input may cause an error in the internal reset.

When you restart/reset the camera or operate the camera by inputting an external trigger shutter pulse, the Vsync signal for the image is output 1 H later from the external VD.

Normal:

1N: Consecutively operated with 32 s HD frequency and 20 ms VD frequency. (See the above figure for the phase timing).

2I: Consecutively operated with 32 s HD frequency and 10 ms VD frequency. (See the above figure for the phase timing).

Restart/Restart and /External trigger shutter

Consecutively operated with 32 s HD frequency. VD (Reset) is on any timing as long as the HD phase is within the range described above.

8