10.5 Environmental Specification

Test Case

Heat Test

Cold Test

Temperature Cycling

Thermal Shock Test

Moist Heat Cyclic Test

Operational Durability

Free Fall Test

Test Summary

Temp: max storage

Humidity: nominal

Duration: 16 hours

Temp: min storage

Duration: 16 hours

Temp (low) : min storage

Temp (high) : max storage

2 hrs dwell at each extreme

6 hrs transition between temps Duration: 5 cycles x 16 hours

(80 hrs total)

Temp (low) : min storage

Temp (high) : max storage

6 min dwell at each extreme

0.5to 3 min transition Duration: 30 cycles (Group 2,3)

Temp (low) : nominal ambient

Temp (high) : max operating

Humidity (high) : 95% ±5% RH

Humidity (low) : 93% ±5% RH 9 hr dwell at each temperature 3 hr transition between temps Duration: 6 cycles x 24 hours

(144 hrs total)

SIM insertion : 500 cycles

System connector : 10,000 cycles

Flips/Hinges : 1,000 cycles

RF connector : 5,000

1m drop height on to concrete

-all sides

-all faces

-all corners

-any extended features

Ref Standard

IEC 60068-2-2

IEC 60068-2-1

IEC 60068-2-14

IEC 60068-2-14

IEC 60068-2-30

1/52 41-FEA 202 8370

IEC 60068-2-32 Test Ed

LZT 123 1834

87