Image 8

Cleaning - Damp wipe only with mild detergent recommended for synthetic fabrics. Remove grease and oil immediately. Always rinse well with fresh water. Read instructions provided on the device.

DO NOT MACHINE WASH

DO NOT MACHINE DRY

DO NOT DRY CLEAN

DO NOT USE SOLVENT BASED CLEANERS

DO NOT BLEACH

C. INSPECTION

Certified Inspection - SOSPENDERS® strongly recommends that this device be inspected at least every 24 months by a certified Repair Facility or SOSPENDERS®.

User’s Inspection - The user should perform the following checks before each season, or before a long journey, or as recommended below:

1.Leak Test - This test should be performed every two months and at the start of each season. (a) Remove the CO2 cylinder (b) Inflate using the oral inflator (c) Leave to rest for 16 hours. When buoyancy cham- ber remains firm and full of air, there is no leakage and chamber is in operational condition. If the chamber deflates, immediately bring to a certified Repair Facility for repair. The device is no longer in opera- tional condition. (d) Deflate, install the CO2 cylinder, inspect to ensure that the PFD is properly armed (Back Cover) and then repack the PFD (page 15) so it’s ready for use.

2.Function Test of Oral Valve - Remove the dust protection cap. With the PFD inflated (see steps a and b of Leak Test), test the valve by pushing it down using the tab provided on the cap (refer to page 6). The valve should depress easily. When released it should automatical- ly return to the closed, resealed position. Prepare the PFD for use (see step d of Leak Test).

3.Physical Inspection of Cover and Straps - Examine outer shell fabric, seams, webbing attachments, buckles, slides; etc. Fabric fading can indicate a loss of strength. Check for strength by pulling seams and attachments snugly. If device shows any signs of damage, return to a certified Repair Facility or replace the entire device. This inspection should be performed each outing.

D.STORAGE

STORE IN CLEAN, COOL, DRY AREA.

DO NOT STORE IN DIRECT SUNLIGHT.