Sound Performance Lab 9530 Specifications, Input & Output, Measurements, Power Supply, Dimensions

Models: 9530

1 20
Download 20 pages 43.18 Kb
Page 19
Image 19
Input & Output

Input & Output

Instrumentation amplifier, electronically balanced (differential), transformerless

Nominal input level

+6 dB

Input impedance

= 22 kOhms

Output impedance

< 600 Ohms

Max. input level

+24 dBu

Max. output level

+22,4 dBu

Minimum load ohms

600 Ohms

Relay Hard Bypass, Power Fail Safety

 

Measurements

Frequency response (without tubes)

10 Hz - 100 kHz

(100 kHz = -3 dB)

 

Frequency response (with tubes)

30 Hz - 100 kHz

(30 kHz = -3 dB)

 

CCMR (common mode rejection)

- 100 dBu at 1kHz

THD & N

0,002% at 1kHz

S/N CCIR 468-3

-83 dBu

S/N A-weightened

-89 dBu

Power Supply

Toroidal transformer

35 VA

Fuse (primary)

500 mA (230 V/50 Hz)

 

... 1000 mA (115 V/60 Hz)

Fuse (secundary)

315 mA (230 V/50 Hz)

 

... 630 mA (115 V/60 Hz)

Ground-Lift switch,Voltage selector

 

Dimensions

Housing

.............................................................. Standard EIA 19"/2U,

 

... 482 x 88 x 237 mm

Weight

4,9 kg

Note: 0 dBu = 0.775 V

Subject to change without notice.

Specifications