GFS SERIES TUBE FRYERS SPECIFICATIONS
OPERATORS MANUAL 1182026 REV 2PAGE 5

SPECIFICATIONS

Gas Supply Requirements and Burner Information

Supply pressure should be greater than 7" W.C. for natural gas or greater t han 11" W.C. for pr opane. One

3/4" NPT male connector located on back (see illustra tions on pages 4 and 7).

Model Burners Gas Type Manifold
Pressure Number
per Unit Rate Each
BTUs/Hour Total Rate
BTUs/Hour Orifice Size
Natural 4" W.C. 3 35,000 105,000 #36 - 0.1065" dia.
Main Propane 10" W.C. 3 30,000 90,000 #52 - 0.0635" dia.
Natural 4" W.C. 1 900 900 #77 - 0.0180" dia.
GFS35
Pilot Propane 10" W.C. 1 900 900 0.0110" dia.
Natural 4" W.C. 4 35,000 140,000 #36 - 0.1065" dia.
Main Propane 10" W.C. 4 30,000 120,000 #52 - 0.0635" dia.
Natural 4" W.C. 1 900 900 #77 - 0.0180" dia.
GFS45
Pilot Propane 10" W.C. 1 900 900 0.0110" dia.
Natural 4" W.C. 5 35,000 175,000 #36 - 0.1065" dia.
Main Propane 10" W.C. 5 30,000 150,000 #52 - 0.0635" dia.
Natural 4" W.C. 1 900 900 #77 - 0.0180" dia.
GFS65
Pilot Propane 10" W.C. 1 900 900 0.0110" dia.
Electrical Requirement

No external electric power is required.

Clearances

See page 9.