Speco Technologies 4WM, 16WM, 8WM setup guide Dome Camera Control, Dome Camera Connection & Settings

Models: 16WM 4WM 8WM

1 12
Download 12 pages 47.96 Kb
Page 7
Image 7
Dome Camera Control

Dome Camera Control

Dome Camera Connection & Settings:

See section Pin Definition of Alarm I/O & RS-485, and Audio In for RS-485 port pin definition.

Connect the R+, R- terminals on the dome camera to the D+, D- terminals on the RS-485 port by RS-485 cable respectively.

To set up dome camera’s protocol and ID, press MENU to access the OSD main menu or change the protocol and ID by using SpecoRemote, and select <Camera Setup>. The available protocols include <Speco>, <DSCP>, <AD422>, <Pelco D>, <Pelco P>, <Fastrax 2>, <JVC>, <Panasonic_C>, and <Panasonic_N>. The default is <None>. Note that ID number must match the ID address defined by the dome camera.

To configure the RS-485 parameters, select <System Setup> from OSD main menu or through SpecoRemote, and then select <RS485 Setup>. The default RS-485 settings are 9600 Baud, 8 Data Bits, 1 Stop Bit and No Parity.