Learning the Receiver Functions

Attaching the Receiver to a Grade Rod

Turning On/Off the Receiver

1.Press the power/audio button to turn on the receiver.

Note: When the receiver is initially turned on/off, all LCD symbols, LEDs, and the audio

signal are turned on for one second. Audio On

2.Press and hold the power/audio button for one second to turn off the receiver.

Selecting the Audio Function

Above Grade

On Grade

Low Battery Below Grade

Using the Receiver with a Laser

1.Press the power/audio button to turn on the receiver. Also make sure the Receiver Mode LED on the 1.5PL laser is RED (if not, press the RECEIVER button on the 1.5PL).

2.Position the receiver so that its photocell faces the laser.

3.Move the receiver up/down until the LCD and LEDs show an on-grade reading.

Note: The LCD shows a down arrow when the receiver is above the laser beam, an up arrow when below it, and a horizontal line when centered in the laser beam. The LED is red for above grade. green for on grade, and blue for below grade.

LCD/LED/Audio Information

 

 

 

 

 

 

 

LED

LCD Readout

 

Function

Audio Output

Indication

Down arrow

 

High

Fast beeping tone

Top red LED:

 

 

 

 

 

 

 

solid

Center bar &

 

Fine-high

Fast beeping tone

Top red LED:

down arrow

 

 

 

 

flashing

Center bar

 

 

 

On-grade

Continuous tone

Middle green

 

 

 

 

 

 

 

 

 

 

LED: solid

Center bar

 

 

 

Fine-low

Slow beeping

Bottom blue

 

 

& up arrow

 

 

tone

LED: flashing

Up arrow

 

Low

Slow beeping

Bottom blue

 

 

 

 

 

 

tone

LED: solid

LCD

1.

Slide the general-purpose clamp into

 

the receiver until it “clicks” into

 

position.

2.

Turn the jaws screw counterclockwise

 

to open the clamp’s jaws.

3.

Slide the survey rod or wooden pole

 

between the clamp’s jaws.

4.

Turn the jaws screw clockwise to hold

 

the general-purpose clamp securely in

The receiver always starts up with the audio mode (loud) active.

1.Press the power/audio button repeatedly to cycle the audio level - loud, low or off.

Note: If the audio function is on, the receiver beeps quickly when the receiver is above the laser beam, slowly when below it, and continuously when centered in the laser beam or on grade.

– 13 –

Laser Setup with a Tripod

– 14 –

Determining the Height of Instrument (HI)

 

 

 

Indication

Battery

Low battery

N/A

Flashing symbol

Horn

Audio Loud

Loud

Solid symbol

 

Audio Low

Low

Flashing symbol

 

Audio Off

None

No symbol

– 15 –

Specifications

place.

– 16 –

1.Set up the tripod in the middle of your work area (or wherever is best for your application needs). Make sure the setup is stable.

Note: The typical operating radius of the system is 75 m (250 ft).

Note: For best system performance, do not set up the laser within 6 m (20 ft) of a wall. Also do not use the receiver within 6 m (20 ft) of the laser or within 1.5 m (5 ft) of a wall. At these close ranges, the receiver’s electronics may give incorrect beam elevation information due to the laser beam reflecting off of the walls.

2.Attach the laser directly to a 5/8 x 11 tripod. Use the optional adapter (p/n 0002-3430) for 1/4 x 20 tripods.

3.Turn on the laser and receiver.

The height of instrument (HI) is the elevation of the laser’s beam. The HI is determined by adding the grade-rod reading to a benchmark or known elevation.

1.Set up and level the laser.

2.Attach the receiver to a grade rod and turn on the receiver.

3.Place the grade rod on a job-site benchmark (BM) or known elevation.

4.Slide the receiver up/down the grade rod until the LCD shows an on-grade reading.

5.Add the grade-rod reading to the benchmark to determine the height of instrument.

Example: Benchmark elevation

=

30.55 m

(100.23 ft)

On-grade rod reading

=

+ 1.32 m

(4.34 ft)

Height of instrument

=

31.87 m

(104.57 ft)

6. Use this HI as a reference for all other elevations.

Height of Instrument (HI)

Laser

 

 

 

Horizontal and Vertical

± 1.0 mm @ 5 m (± 1/32 in. @ 17 ft)

Lines 1,2

 

Down Point Beam Accuracy 1,2

± 0.4 mm @ 1 m (± 1/32 in @ 3 ft)

Self-Leveling Range

± 3° from level

Out-of-Level Indicator

Beam Flashes, Vial lights RED and Beeping

 

Warning Tone

Visual Working Range

30 m (100 ft)

Manual Mode and

LED On and Vial lights RED

Compensator Lock Indicator

 

Laser Class / Type

3A/3R; 635 nm

Line Beams Fan Angle

200° Horizontal / 120° Vertical (200°+ total of

 

both lines)

Power Source

NiMH-recharge pack + backup 4 AA alkaline

Battery Life 1

> 7 hours, All beams on (NiMH/alkaline)

Low-Battery Indicator

POWER LED flashes RED

Operating Temperature Range

–10 °C to 45 °C (14 °F to 113 °F)

Size

H24.0 x W13.8 x D12.1 cm (9.45 x 5.4 x 4.77 in)

Weight (Transmitter w/

1.54 kg (3.39 lbs)

Receiver

Accuracy

Elevation Readout

Audio Control

Capture Height

Marking Notches

Power Source

Battery Life

Low-Battery Indicator

Automatic Shutoff

Drop Resistance

Water Proof / Dust Proof

Operating Temperature

Storage Temperature

Regulatory Conformance

±1.0 mm (±1/32 in.)

Front LCD and simultaneous rear corner LEDs (red, green, and blue)

Loud / Low / Off

50 mm (2 in.)

50 mm (2 in.) below top of receiver

2 AA alkaline batteries

50+ hours

Flashing battery symbol on LCD

30 minutes after last laser strike or button press

1.5m (5 ft) onto concrete at room temperature Yes - IP67

–20 °C to 60 °C (–4 °F to 140 °F) –40 °C to 70 °C (–40 °F to 158 °F) 2004/108/EC; 2002/95/EC; 2002/96/EC

6 m (20 ft)

6 m (20 ft)

5 ft (1.5 m)

minimum

minimum

minimum

17

Request for Service

To locate your local dealer or authorized Trimble Service Center outside the U.S.A for service, accessories, or spare parts, contact one of our offices listed below.

North & Latin America

Asia-Pacific

Trimble Spectra

Trimble Navigation Singapore

Precision Division

PTE Ltd.

8261 State Route 235

80 Marine Parade Road, #22-06

Dayton, Ohio 45424

Parkway Parade

U.S.A.

Singapore, 449269

(800) 538-7800 (Toll Free)

+65 6348 2212 Phone

+1-937-245-5600 Phone

+65 6348 2232 Fax

+1-937-482-0030 Fax

China

 

Europe

Trimble Beijing

Trimble Kaiserslautern GmbH

Room 2805-07, Tengda Plaza,

Am Sportplatz 5

No. 168 Xiwai Street

67661 Kaiserslautern

Haidian District

GERMANY

Beijing, China 100044

Tel +49-(0)6301-71 14 14

+86 10 8857 7575 Phone

Fax +49-06301-32213

+86 10 8857 7161 Fax

Africa & Middle East

www.trimble.com.cn

 

Trimble Export Middle-East

 

P.O. Box 17760

 

Jebel Ali Free Zone, Dubai

 

UAE

 

+971-4-881-3005 Phone

 

+971-4-881-3007 Fax

 

Rod Reading 1.32 m (4.34 ft)

Benchmark

30.55 m (100.23 ft)

HI = Rod Reading + Benchmark

HI = 1.32 m + 30.55 m = 31.87m (4.34 ft + 100.23 ft = 104.57 ft)

18

Maintenance and Care

Handling Precautions

When transferring the laser from a very low temperature to a warmer environment or visa versa, always allow time for the laser to reach the new temperature before using. Allowing this time is especially important when transferring the laser from an extremely heated/cold vehicle to the job site.

System Cleaning

For maximum performance and accuracy always keep the windows clean. When cleaning, apply very light pressure and use only a good quality glass cleaner on a soft cloth to clean the exterior of the laser and its windows.

CAUTION: A dry cloth or abrasive organic cleaner could scratch or damage these surfaces.

CAUTION: Do not submerge the laser.

Storage

When you’re not using the laser, store it in its pouch/carrying case.

CAUTION: Do not store the laser in a wet pouch/carrying case. If the pouch/carrying case gets wet, let it dry before storing the laser in it.

Calibration

Before each use, be sure to check the laser for signs of damage. If the laser has been dropped or subjected to other rough treatment, it should be checked for accuracy. For instruction on checking calibration, please visit our website support list at www.trimble.com/support.shtml

Batteries)

1)at 21° C (70° F)

2)along the axis

– 19 –

Warranty

Trimble warrants the 1.5PL to be free of defects in material and workmanship for a period of one year. Trimble or its authorized Dealer or service center will repair or replace, at its option, any defective part, or the entire product, for which notice has been given during the warranty period. This warranty period is in effect from the date the system is delivered by Trimble or its authorized Dealer to the purchaser, or is put into service by a Dealer as a demonstrator or rental component.

Customers should send products to the nearest Authorized Factory, Dealer, or Service Center for warranty repairs, freight prepaid. In countries with Trimble Service Subsidiary Centers, the repaired products will be returned to the customer, freight prepaid.

Any evidence of negligent, abnormal use, accident, or any attempt to repair equipment by other than factory-authorized personnel Trimble certified or recommended parts, automatically voids the warranty.

Special precautions have been taken to ensure the calibration of the laser; however, calibration is not covered by this warranty. Maintenance of the calibration is the responsibility of the user.

The foregoing states the entire liability of Trimble regarding the purchase and use of its equipment. Trimble will not be held responsible for any consequential loss or damage of any kind.

This warranty is in lieu of all other warranties, except as set forth above, including an implied warranty merchantability of fitness for a particular purpose, is hereby disclaimed. This warranty is in lieu of all other warranties, expressed or implied.

Notice to Our European Union Customers

For product recycling instructions and more information, please go to: www.trimble.com/environment/summary.html

Recycling in Europe

To recycle Trimble WEEE, call: +31 497 53 2430, and ask for the “WEEE associate,” or

mail a request for recycling instructions to: Trimble Europe BV

c/o Menlo Worldwide Logistics Meerheide 45

5521 DZ Eersel, NL

– 20 –

Laser Safety

Use of this product by people other than those trained on this product may result in exposure to hazardous laser light.

Do not remove warning labels from the unit.

The 1.5PL is a Class 3A/3R (635 nm) laser.

Never look into the laser beam or direct it to the eyes of other people.

Always operate the unit in a way that prevents the beam from getting into people‘s eyes.

Trimble Spectra Precision Division

8261 State Route 235

Dayton, Ohio 45424-6383

U.S.A.

www.trimble.com/spectra

© 2011, Trimble Navigation Limited. All rights reserved. Reorder PN 1213-0803 (2/11)

– 21 –

– 22 –

– 23 –

Page 2
Image 2
Spectra 1.5PL manual LCD/LED/Audio Information, Laser Setup with a Tripod, Specifications, Request for Service, Calibration

1.5PL specifications

The Spectra 1.5PL is an advanced imaging system that has gained recognition in various industries, including medical, engineering, and research. As a state-of-the-art device, it offers a multitude of features, technologies, and characteristics that set it apart from other imaging solutions in the market.

One of the primary features of the Spectra 1.5PL is its high-resolution imaging capabilities. The system utilizes a powerful sensor that captures images with exceptional clarity and detail, making it suitable for applications where precision is critical. The 1.5PL model boasts a resolution of 2048 x 2048 pixels, allowing users to observe fine details that are often missed by lower-resolution systems.

Another significant aspect of the Spectra 1.5PL is its versatility. The device supports various imaging modalities including fluorescence, dark field, and phase contrast, providing researchers and professionals with the flexibility to choose the best imaging technique for their specific needs. This adaptability is essential in fields such as microbiology and pathology, where different techniques may be required to visualize different specimen types.

The Spectra 1.5PL also integrates advanced imaging technologies. One notable technology is its automated control system that enhances ease of use and reduces the learning curve for new users. The automated focus and exposure settings optimize image quality while minimizing human error during image acquisition.

Additionally, the system comes equipped with powerful software that enables users to analyze and process images efficiently. The software provides a suite of tools for enhancing images, measuring dimensions, and even performing quantitative analysis. This is particularly beneficial for researchers who need to compile data from their imaging studies.

The design of the Spectra 1.5PL reflects its commitment to user comfort and efficiency. With an ergonomic layout and intuitive interface, users can navigate through different functions seamlessly. This thoughtful design enhances productivity in bustling laboratory environments.

Moreover, the rugged construction of the Spectra 1.5PL ensures reliability and durability. It is engineered to withstand the demands of a busy workspace, making it a long-term investment for institutions and labs looking for dependable imaging solutions.

In conclusion, the Spectra 1.5PL stands out with its high-resolution imaging, versatile modalities, automated control system, powerful software, user-friendly design, and robust construction. These features make it an essential tool for professionals seeking high-quality imaging solutions across various scientific and industrial applications.