Action
Turn power ON/OFF
DisplayRemarks
Action
CAPTURE Function
A) HL700 is in the laser beam and the |
Display
The current elevation read-
Remarks
Press any switch to return to normal
Press and hold for 2 seconds to turn power OFF.
1
2
Initialization:
1.Test of LCD, LED and beeper
2.CAL: Calibration (3 sec.)
3.Unit is ready for use.
(Do not power up the unit in a laser beam or strobe. If detected, the unit will display “E200” and revert to the previous
power is on: |
1 x quick
ing will be held. A flashing display will confirm the reading has been captured.
operation.
Select accuracy
Press once to change current setting (A beep confirms the selected volume.)
Select beeper volume
3
Accuracy in mm:
0.5 1.0 2.0 5.0 10.0
calibration.)
The selected unit of measure determines the displayed deadband (accuracy).
The current accuracy is stored in memory and will be retained when the unit is turned off or when batteries are replaced.
B)HL700 is out of the laser beam and power is on:
1.
1 x quick
2. Place the HL700 in the beam. (Example: |
Fasten it to a measuring rod, bring the |
HL700 into the laser beam. You now have |
A short intermittent
+beep (The beeper will turn on to Low if turned off.)
The beeper will
+chirp rapidly after approximately 5
Press any switch to return to normal operation.
Press once to display current setting; push again to scroll through options.
Select units of measure
Press once to display current setting, additional pushes to scroll through options.
|
|
| (No symbol) | The current beeper |
Beeper | Beeper | Beeper | Beeper | volume is stored in |
memory and will be | ||||
Loud | Medium | Low | Off | retained when the unit is |
|
|
|
| turned off or when bat- |
|
|
|
| teries are replaced. |
mm - cm - in - frac - ft | The current unit of measure is stored in |
| memory and will be retained when the unit |
| is turned off or when batteries are replaced. |
5 seconds to plumb the rod and get the |
reading captured.) |
Special Menu Functions
Press switches together for 2 sec.
+
How to change Menu functions:
seconds to confirm beam capture. A flashing display will also indicate the reading has been captured.
| (for 2 Sec., then SENS) |
SENS | Sensitivity |
AVG | Averaging algorithm Medium*High - Low |
D.R.O. | Numeric display |
UNIT | Units of measure |
FRC.R. | Fractional Reduction |
ARRW | Arrow Display |
O.O.B. | |
GRD.A. | Grade Alarm |
A.S.O. | Automatic shutoff |
TX.O.L. | Transmitter |
TX.O.B. | Transmitter Low Battery |
Change special Menu Functions only in the case of special job requirements!
Sensitivity of reception
SENS (Sensitivity):
Selects reception sensitivity to laser and other light sources.
MD - Medium*: for most applications.
HI - High: When laser beam is weak, or at very long distances.
LO - Low: If outside sources are disturbing elevation readings.
Grade Alarm
Select brightness of LEDs
|
| (No symbol) | The current brightness of LEDs |
LEDs | LEDs | LEDs | is stored in memory and will |
be retained when the unit is | |||
Bright | Dim | OFF | turned off or when batteries are |
|
|
| replaced. |
+
Press together to cycle the selection.
1. Scrolling up or down.
2. Enter Change mode.
3. Change selected items.
4. Confirm change.
5. To Exit. | or |
|
INFO | Information about the Laserometer |
Automatic Shutoff
A.S.O. (Automatic Shut Off):
0.5 - After 30 Minutes*
OF - Off (Unit is permanently on.) 24 - 24 hour shutoff.
Out-of-Beam Display
O.O.B.
ON -
OF -
GRD.A. (Grade Alarm):
When turned ON, disables the audible signal when
ON - Alarm on (Solid beeper OFF) OF - Alarm off (Solid beeper ON)*
* Default setting
For more information about special Menu Function contact the