SPECTRA SERIES 29

6.9 ONE-TOUCH ARMING*
Section [130]: Options [1] to [4]
Option [1] ON = Press & hold the [ENTER] key for One-touch Regular Arming.
Option [2] ON = Press & hold the [STAY] key for One-touch Stay Arming.
Option [3] ON = Press & hold the [FORCE] key for One-touch Force Arming.
Option [4] ON = Press & hold the [BYP] key for One-touch Bypass Programming.
The One-touch Arming features allow users to arm the system without having to enter any access codes. To arm the
system, press and hold the appropriate key (see above) for approximately 2 seconds. If the system is partitioned
(see page 43), you must also press the key corresponding to the partition you wish to arm. For more information on
the different arming methods, please refer to page 52.
6.10 EXIT DELAY**
Section [071] = Partition 1, [072] = Partition 2
001 to 255 seconds, Default = 30 seconds
After entering the required arming sequence (i.e. User Access code, etc.), the Exit Delay parameter determines the
amount of time a user has to leave the protected area before the control panel arms the partition. The Exit Delay
applies to all zones in the selected partition. When enabled, the keypad will beep once every second during the Exit
Delay and will beep rapidly during the final 10 seconds of the Exit Delay.

6.10.1 BEEP ON EXIT DELAY

Section [130]: Arming/Disarming Options
Option [8] OFF = Beep on Exit Delay Disabled
Option [8] ON = Beep on Exit Delay Enabled (default)
6.11 BELL SQUAWK ON ARM/DISARM WITH KEYPAD
Section [130]: Arming/Disarming Options
Option [7] OFF = Bell Squawk on Arm/Disarm Disabled (default)
Option [7] ON = Bell Squawk on Arm/Disarm Enabled
When this feature is enabled, the bell or siren will squawk once upon arming and twice upon disarming.
6.12 BELL SQUAWK ON ARM/DISARM WITH REMOTE CONTROL
Section [131]: Arming/Disarming Options
Option [3] OFF = Bell Squawk on Arm/Disarm with Remote Control Disabled (default)
Option [3] ON = Bell Squawk on Arm/Disarm with Remote Control Enabled
When this feature is enabled, the bell or siren will squawk once upon arming with a remote control and twice upon
disarming with a remote control. Must be enabled for UL installations.
6.13 NO EXIT DELAY WHEN ARMING WITH REMOTE CONTROL
Section [131]: Arming/Disarming Options
Option [4] OFF = Provides Exit Delay When Arming with a Remote Control (default)
Option [4] ON = No Exit Delay When Arming with a Remote Control
When the option is enabled, the panel cancels the Exit Delay (arms instantly) when a partition is armed with a
remote control. When disabled, the Exit Delay timer will start when a partition is armed with a remote control.
6.14 NO EXIT DELAY BEEPS AND NO BELL SQUAWK WHEN STAY ARMING
Section [131]: Arming/Disarming Options
Option [5] OFF = No Exit Delay Beeps and No Bell Squawk When Stay Arming Disabled (default)
Option [5] ON = No Exit Delay Beeps and No Bell Squawk When Stay Arming Enabled
With this feature enabled, the control panel will prevent the bell or siren from squawking and the keypads from
beeping during the Exit Delay, whenever a partition is Stay Armed.
* Not to be used with UL installations
** Maximum 60 seconds for UL listed systems