24 REFERENCE & INSTALLATION MANUAL
5.8.1 AUTO ZONE SHUTDOWN
Sections [001] to [016] = Zones 1 to 16
Option [1] OFF = Auto Zone Shutdown Disabled
Option [1] ON = Auto Zone Shutdown Enabled for selected zone (default)
If, in a single armed period, the number of alarms generated by a zone with the Auto Zone Shutdown
option enabled exceeds the number defined by the Auto Zone Shutdown Counter, the control panel will no
longer generate an alarm for that zone. To program the Auto Zone Shutdown Counter, key in the desired
limit (000=Disabled, 001 to 015, Default = 5) into section [089]. The Auto Zone Shutdown Counter resets
every time the system is armed.
5.8.2 BYPASS ZONES
Sections [001] to [016] = Zones 1 to 16
Option [2] OFF = Bypass Zone Disabled
Option [2] ON = Selected Zone is Bypass Enabled (default)
When a user, utilizes the Bypass Programming feature (see page53), only zones with t he Bypass option
enabled can be programmed as bypassed.
Do not program a Fire Zone with the Bypass option, as the control panel will never bypass
Fire Zones.
5.8.3 STAY ZONES
Sections [001] to [016]: Zones 1 to 16
Option [3] OFF = Stay Zone Disabled (default)
Option [3] ON = Selected Zone is Stay Enabled
Zones with the Stay option enabled will be bypassed when the system is Stay Armed (see page 52).
Do not program a Fire Zone with the Stay option, as the control panel will never bypass Fire
Zones when Stay Arming.
5.8.4 ALARM TYPES
Sections [001] to [016]: Zones 1 to 16
[4] OFF / [5] OFF: Audible Steady (default)
When the conditions for an alarm have been met, the control panel can transmit the appropriate Zone
Alarm report code (see page34) and provides a steady output for any bells or sirens connected to the
control panel’s bell output.
[4] OFF / [5] ON: Audible Pulsed Alarm
When the conditions for an alarm have been met, the control panel can transmit the appropriate Zone
Alarm report code (see page34) and provides a pulsed output (see Figure 5-2 on page 22) for any bells or
sirens connected to the control panel’s bell output.
[4] ON / [5] OFF: Silent Alarm
When the conditions for an alarm are met, the control panel can transmit the appropriate Zone Alarm
report code (see page 34) and will not activate the control panel’s bell output. The appropriate ARM or
STATUS LED on the keypads will flash to indicate an alarm and the user will still have to disarm the system.
[4] ON / [5] ON: Report Only
When the conditions for an alarm have been met, the control panel can transmit the appropriate Zone
Alarm report code (see page34). The system will not have to be disarmed.
5.8.5 INTELLIZONE
Sections [001] to [016]: Zones 1 to 16
Option [6] OFF = Intellizone Disabled (default)
Option [6] ON = Intellizone Enabled for Selected Zone
This feature reduces the possibility of false alarms. When a zone with the Intellizone option opens, the
panel does not immediately generate an alarm. First it triggers the Intellizone Delay Timer. To pro gr am t he
Intellizone Delay Timer, key in the desired 3-digit value (010 to 255 seconds, Default = 48 seconds) into
section [084]. If any of the following conditions occur during this period, the panel will generate an alarm:
• During the Intellizone Delay, a second zone has caused an alarm.
• During the Intellizone Delay, the zone in alarm has restored (closed) and re-occurred (opened).
• The zone in alarm remains open for the entire Intellizone Delay.