SPECTRA SERIES 45

10.10 CONFIDENTIAL MODE
Section [126] Options [1], [2] and [3]
Option [1] OFF = Confidential Mode Disabled (default)
Option [1] ON = Confidential Mode Enabled
Option [2] OFF = Keypads activate when an access code is entered
Option [2] ON = Keypads activate when a key is pressed (default)
Option [3] OFF = Confidential Mode Timer is 2 minutes
Option [3] ON = Confidential Mode Timer is 5 seconds (default)
If Confidential Mode is enabled and no actions are performed on the keypads for the time defined by the
Confidential Mode Timer, all the keypads’ LEDs will be off and LCD screens will show “Paradox Family” until either a
key is pressed or an access code is entered. When the system exits Confidential Mode, the keypads will display the
system’s status. Confidential Mode is activated by enabling option [1]. Option [2] regulates whether the keypads will
be activated at the touch of a key or only when an access code is entered. Option [3] determines the amount of time
without action before the system enters Confidential Mode (5 seconds or 2 minutes).
10.11 INSTALLER QUICK FUNCTIONS KEYS
After entering the Installer Code, you can press a key to perform specific actions as described below.

10.11.1 INSTALLER TEST MODE

[ENTER] + [INSTALLER CODE] + [TBL] OR [TRBL]
The Installer Test Mode allows you to perform walk tests where the bell or siren will squawk and the
keypad will emit a Confirmation Beep to indicate opened zones. To enter this mode, simply enter the
Installer Code then press the [TBL] or [TRBL] key. The keypad will emit a confirmation beep. To disable this
mode, press the [TBL] key again. The keypad will emit a Rejection Beep.

10.11.2 TEST REPORT

[ENTER] + [INSTALLER CODE] + [MEM]
Sends the Test Report report code programmed in section [211] to the central station (see Reporting and
Dialer settings on page 32).

10.11.3 CALL WINLOAD SOFTWARE

[ENTER] + [INSTALLER CODE] + [BYP]

Refer to page49.

10.11.4 CANCEL COMMUNICATION

[ENTER] + [INSTALLER CODE] + [STAY]

Cancels all communication until the next reportable event.

10.11.5 ANSWER WINLOAD SOFTWARE

[ENTER] + [INSTALLER CODE] + [FORCE]

Refer to page49.
10.12 4-OUTPUT BUS MODULE SUPERVISION
Section [129]: General Options
Option [7] OFF = 4-Output Bus Module Supervision Disabled (default)
Option [7] ON = 4-Output Bus Module Supervision Enabled
By enabling this option, the control panel will supervise the 4-Output Bus Module (APR3-PGM4) connected to the
Spectra bus. This means that whenever the 4-Output Bus Module is disconnected or is not communicating with the
control panel, the control panel will attempt to transmit the Module Fault report code programmed in section [210]
and the Module Loss Failure will appear in the keypads’ Trouble Display (see page50).
Modules with the APR- prefix are compatible with Spectra (versions 2.0 and higher) and Digiplex. Modules
with the APR3- prefix are compatible with Spectra( versions 2.0 and higher), Digiplex and DigiplexNE.