Installation and Operation Manual
Date: 6/02/2008 9
27-0027-0111
SCI P/N: 72A-196BAREM Series
72A-190BQREM Series
The LAN module consists of integrated hardware and a network agent
softwareprogram.Thesecomponentsprovidetheabilitytocongure,
control, and monitor aspects of multiple units using a standard web
browser. The network interface can operate using Telnet and SNMP.
TheLANmoduleisconguredatthefactorytoanIPAddressof
192.168.1.110 and subnet mask of 255.255.255.0. A default gateway ad-
dress of 192.168.1.1 and a SNMP trap address of 192.168.1.200 are also
provided.
The Login dialog box requests a username and password. The factory
default username and password are “root” and “1234”, respectively. This
username has full privileges to set up, maintain, and control the unit.
LAN Module IP Address, DHCP, and Auto IP
Connections and Installation
The LAN module supports three IP assignment methods: Static IP ad-
dress, DHCP, and Auto-IP. If a static address is enabled, it will be used.
If a static address is not enabled, and Auto-IP is enabled, it will be used
to generate an address ONLY if DHCP is disabled, or if DHCP is enabled
and a DHCP server has not responded to the DHCP query. If both are
enabled, Auto-IP has assigned an address, and then a DHCP server
responds. The Auto-IP address will be discarded and the DHCP address
will be used.
Other Factory Defaults:
SNMP Enabled
SNMP Community Name Public
Telnet Setup Enabled
FTP Download Enabled
Web Server Disabled - Can enable with
future Firmware Update
Web Setup Disabled
ECHO Disabled
AutoIP allows the unit to obtain an address in a network that does not
have a DHCP server. AutoIP assigns a random valid address to the LAN
module in the range of 169.254.x.x to 169.254.x.x where x is between 0
and 255 and a Netmask of 255.255.0.0.