72 MI.20xx Manual
Channel Trigger Trigger modes and appendant registers
Channel window trigger for short inner signals
The analog input is continuously sampled with the selected
sample rate. The upper and the lower levels define a win-
dow. Every time the signal enters the window from the out-
side, the pulsewidth counter is startet. If the pulsewidth
counter stops and the signal is still inside the window, no
trigger will be detected.
If the signal leaves the window before the pulsewidth coun-
ter has stopped, the triggerevent will be detected.
Channel window trigger for short outer signals
The analogd input is continuously sampled with the selected
sample rate. The upper and the lower levels define a win-
dow. Every time the signal leaves the window from the insi-
de, the pulsewidth counter is startet. If the pulsewidth
counter stops and the signal is still outside the window, no
trigger will be detected.
If the signal enters the window before the pulsewidth coun-
ter has stopped, the triggerevent will be detected.
Register Value Direction set to Value
SPC_TRIGGERMODE 40000 r/w TM_CHANNEL 20040
SPC_TRIGGERMODE0 40200 r/w TM_CHXWINENTER_SP 10042
SPC_HIGHLEVEL0 42000 r/w Sets the window’s upper level relatively to the channel’s input range. board dependant
SPC_LOWLEVEL0 42100 r/w Sets the window’s lower level relatively to the channel’s input range. board dependant
SPC_PULSEWIDTH 44000 r/w Set to the desired pulsewidth in samples. 2 to 255
Register Value Direction set to Value
SPC_TRIGGERMODE 40000 r/w TM_CHANNEL 20040
SPC_TRIGGERMODE0 40200 r/w TM_CHXWINLEAVE_SP 10052
SPC_HIGHLEVEL0 42000 r/w Sets the window’s upper level relatively to the channel’s input range. board dependant
SPC_LOWLEVEL0 42100 r/w Sets the window’s lower level relatively to the channel’s input range. board dependant
SPC_PULSEWIDTH 44000 r/w Set to the desired pulsewidth in samples. 2 to 255