Cleaning & Maintenance
Cleaning Your Shaver
Remington® recommends cleaning your shaver after every use for optimal performance.
1.Turn the shaver OFF.
2.
brush to clean the screen. Instead, blow the shavings out or rinse the screen under cold or warm water.
3. Cutters and trimmer-
Use the cleaning brush to sweep any loose hairs from the cutters and trimmers, or rinse/dunk them in cold or warm water. Do not use hot water.
4. After cleaning, return the foil and head assembly to their original position on the shaver.
5.If the shaver was rinsed with water, or if you used it in the shower, hold it facing downward into the sink, and turn it on for a
few seconds to dispel additional water. A gentle shake will also help.
6.To clean the external
surfaces of the shaver, use a damp cloth. Do NOT use strong detergents or other chemicals.
7.To dry, wipe the surface of the overall shaver with a dry towel. Do NOT use a hairdryer or heater to dry the shaver.
U.S. residents:
To order shaver accessories call 800.736.4648, visit
To replace a cutter assembly that is removed unintentionally:
1.Hold the cutter in the middle. The blades will not cut your fingers, so no special handling techniques are necessary.
2.Align the cutter so the little bar on the bottom meets the opening in the clip.
3.Press down on the center of the cutter until it snaps into place. Do not push down on the ends of the cutter, as you may bend the cutter, reducing its ability to cut cleanly.
4.Do not separate the cutter’s blades from the plastic pieces they are attached to, as this may damage the assembly.
Rechargeable Battery
Removal
When your
CAUTION: DO NOT PUT IN FIRE OR MUTI- LATE YOUR BATTERIES WHEN DISPOSING AS THEY MAY BURST AND RELEASE TOXIC MATERIALS. DO NOT SHORT CIRCUIT AS IT MAY CAUSE BURNS. DISPOSE PROPERLY IN ACCORDANCE WITH YOUR LOCAL AND STATE REQUIREMENTS.
How to Remove the Rechargable Battery:
1.Press the head release button to open the shaver’s head assembly.
2.Pull the cutters off the cutter drives that hold them.
3.Use a torx screwdriver to remove screws from back of shaver. (A.)
4.Pry housing halves apart, starting at the head. (B.)
5.Unscrew PCB from housing. (C.)
6.Cut the 2 metal tabs connecting the batteries to the printed circuit board. (D.)
7.Pull the batteries and the printed circut board free from the inner frame and dispose of properly. (E.)
B.
A.
C. C.
D. D.