LIGHTING AND SHUTTING DOWN
GAS IGNITION SYSTEM
1.Turn machine disconnect switch, located on rear of tumbler, to the “on” position.
2.Turn gas
3.Start tumbler, following operating instructions which accompanied it.
NOTE: Ignition control circuitry will verify airflow switch, located on rear of tumbler, is open before starting cylinder motor. Once cylinder motor is started, air flowing through tumbler will cause airflow switch to close. Tumbler will purge air from tumbler for 18 seconds. Ignition will start by a three second release of gas from gas valve and sparking of ignitor. If ignition does not occur
during first three seconds ignition control will “lockout” causing gas valve to close and a red button on ignition control to illuminate.
To reset ignition system , open access door and press red button on ignition control. Close and lock access door, verify that gas
4.If tumbler will not start, remove it from service by turning machine disconnect switch, located on rear of tumbler, to the “off” position and turn the gas
TO GAS VALVE |
|
|
|
|
| ELECTRONIC |
|
|
|
| ||||
|
|
|
|
|
| IGNITION |
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| POWER TO |
SPARK | GAS | IGNITION SYSTEM |
IGNITER |
| |
VALVE |
| |
|
|
T261IE3B
Figure 26
M412616 | 49 |