STEAM CONNECTIONS (Steam Drying Tumblers)
NOTE: See Figure 25 for sizing of steam lines. Piping must also be sized accordingly for length of runs, and number of elbows.
SUPPLY
RETURN
UNION
CHECK
VALVE
TRAP WITH
STRAINER
STEAM
BONNET
RELIEF
VALVE
SOLENOID
VALVE
(Supplied with
machine)
OPTIONAL |
|
VACUUM |
|
BREAKER CONDENSATE |
|
RETURN LINE |
|
FROM | CHECK |
SUPPLY LINE | VALVE |
30.5cm (12")
RISERS
GATE
VALVE
T262IE3A
Figure 24
TUMBLER | STEAM PRESSURE | MINIMUM | STEAM TRAP SIZE |
MODEL | (PSI) | PIPE DIAMETER | (Pounds Condensate/Hour) |
|
|
|
|
30CSL | 3/4" (1.9 cm) | 140 | |
|
|
|
|
30 CSH | 3/4" (1.9 cm) | 140 | |
|
|
|
|
50 CSL | 3/4" (1.9 cm) | 140 | |
|
|
|
|
50 CSH | 3/4" (1.9 cm) | 160 | |
|
|
|
|
75 CSL | 3/4" (1.9 cm) | 140 | |
|
|
|
|
75 CSH | 3/4" (1.9 cm) | 160 | |
|
|
|
|
|
| Figure 25 |
|
48 | M412616 |