DRYING TUMBLER ENCLOSURE CONSTRUCTION
IMPORTANT: DO NOT block airflow at top rear of tumbler with laundry, etc. Doing so would prevent adequate air supply to tumbler’s heat chamber.
A typical tumbler enclosure is shown in Figure 23. Note that enclosure does touch tumbler top and side panels. Note, too, minimum and maximum dimensions. Be aware that there may be local codes and ordinances which must be complied with.
WARNING
To reduce the risk of serious injury, install lockable doors to prevent public access to rear of tumblers.
IMPORTANT: Install tumblers with sufficient clearance for servicing and operating, see Figure 23.
NOTICE: CLEARANCE OF TUMBLER CABINET FROM COMBUSTIBLE
CONSTRUCTION MUST BE A MINIMUM OF 12 INCHES (30.5 cm) AT TOP.
NOTE: Shaded areas |
| 4" (10.16 cm) | 12" (30.5 cm) | |
| MINIMUM | |||
indicate adjacent structure. |
| MAXIMUM | ||
0" CLEARANCE | CLEARANCE | |||
|
| |||
| PERMITTED FOR |
|
| |
| FIRST 4" (10.16 cm) |
|
|
GUARD
PROVISION
FOR
AIR
T038IE3B
24" (61 cm)
MINIMUM
36" (91.4 cm)
0" CLEARANCERECOMMENDED FOR
MAINTENANCE
PURPOSES
Figure 23