Standard Horizon DS41 owner manual Appendix a Dual Station Operation, Master/Slave Selection

Models: DS41

1 17
Download 17 pages 12.58 Kb
Page 15
Image 15

Appendix A – Dual Station Operation

Multiple DS41 instruments can be installed on a single vessel. These instruments can be connected together and configured to operate in a dual station configuration. One instrument is designated as a master and all other instruments, connected to it, are configured as slaves. The master device is connected to the depth transducer and determines the water depth. This information is then displayed on all slave devices connected to it. Slave devices do not have transducers connected to them.

The slave devices can be configured to operate as fully functional NMEA repeaters where they display water depth, as displayed on the master device, and share common alarm settings and keel offset values. In this mode the common alarm settings can be changed or activated/ deactivated from either the master or slave devices.

Alternatively, the slaves can be configured to operate as independent slaves. In this mode the slaves display the water depth received from the master, but have independent alarm settings and keel offset values.

Note:

The instrument designated as the master device is the only instrument connected to the depth transducer.

Master/Slave Selection

To select the master/slave mode of operation:

1. Apply power while holding down the # key.

￿OFF

Hold down during power up

2.When the unit is on. The display will indicate the current display unit:

￿￿￿ example

3.Continue to hold the # key until the display indicates the current master/slave selection.

Master

See the Wiring Connection section for dual station wiring details. Also see the Instrument Setup section for configuration details.

Slave

4.Use the " and # keys to change the selection.

5.To exit this mode, press and hold both the " and # keys simultaneously. Alternatively, if no keys are pressed for a period of 5 seconds normal depth display will resume.

ON￿ ￿OFF

Press simultaneously

Note: When a slave has no depth

information, the display will

alternate between -- and -SL. This will occur if the master unit has no depth reading or if the data link from the master is inadvertently broken.

14DS41 Owner’s Manual

Page 15
Image 15
Standard Horizon DS41 owner manual Appendix a Dual Station Operation, Master/Slave Selection