SPECIFICATIONS |
| |
Pressure Range | ||
Flow Range | ||
Nominal Flow | 8 gpm / 30 lpm | |
Maximum Back Pressure | 250 Psi/17 bar | |
Couplers | HTMA/EHTMA Flush Face Type Male and Female | |
Connect Size & Type | 3/8 in. Male Pipe Adapter | |
Weight | ||
| ||
Overall Length | ||
| ||
Overall Width at Handles | ||
| ||
Max. Fluid Temperature | 140 °F / 60 °C | |
System Type | Open or Closed Center | |
Port Size | SAE 8 | |
HTMA/EHTMA Category | Type 2 | |
Nominal Pressure | 1500 psi/103 bar | |
Max Pressure | 2500 psi/172 bar | |
Max Relief Pressure | 2150 psi/148 bar | |
BR67 SOUND AND VIBRATION DECLARATION |
|
|
TEST CONDUCTED ON BR6717801,OPERATED AT STANDARD 8 GPM INPUT. |
| |
MEASURED | ..........................103 DBA | |
UNCERTAINTY, KWA, IN DECIBELS | 1.7 DBA | |
GUARANTEED SOUND POWER LEVEL | 105 DBA | |
MEASURED | ||
DECIBELS | 99 DBA | |
UNCERTAINTY, KPA, IN DECIBELS | 3 DBA |
VALUES DETERMINED ACCORDING TO NOISE TEST CODE GIVEN IN ISO 15744, USING THE BASIC STANDARD ISO3744. TEST CONDUCTED BY INDEPENDENT NOTIFIED BODY TO COMPLY WITH 2000/14/ EC:2005 REQUIREMENTS. NOTE- THE SUM OF A MEASURED NOISE EMISSION VALUE AND ITS ASSO- CIATED UNCERTAINTY REPRESENTS AN UPPER BOUNDARY OF THE RANGE OF VALUES WHICH IS LIKELY TO OCCUR IN MEASUREMENTS.
BR67 ANTI-VIB MODELS
DECLARED VIBRATION EMISSION VALUE IN ACCORDANCE WITH
MEASURED VIBRATION EMISSION VALUE: | 12.7 M/SEC² |
UNCERTAINTY: K | 1.9 M/SEC² |
MEASURED VIBRATION EMISSION VALUE WITH UNCERTAINTY: | 14.6 M/SEC² |
MEASURED VIBRATION EMISSION VALUE: | 11 M/SEC² |
UNCERTAINTY: K | 2.3 M/SEC² |
MEASURED VIBRATION EMISSION VALUE WITH UNCERTAINTY: | 13.3 M/SEC² |
BR67 |
|
MEASURED VIBRATION EMISSION VALUE: | 18.3 M/SEC² |
UNCERTAINTY: K | 0.7 M/SEC² |
MEASURED VIBRATION EMISSION VALUE WITH UNCERTAINTY: | 19.0 M/SEC² |