10
Dip Switch Settings - Serial Interface Type
No. 1
DIP-SW1
2345678
No. 1
DIP-SW2
2 3 4
DIP-SW 1
Switch 1-1 Command emulation
ON Star Mode
OFF ESC/POS Mode

All factory settings for DIP switch on the auto cutter model are set at on.

Switch 1-3 on the tear bar model is set at off, and the others are set at on.

(1) Star mode

Switch
Function ON OFF
1-1 Command emulation Always ON
1-2
Should not be changed (Should be set to on)
1-3 Auto cutter Valid Invalid
1-4 Sensor adjustment Invalid Valid
1-5 Should not be changed (Should be set to on)
1-6 Handshaking conditions Offline or receive Receive buffer full
(conditions for BUSY) buffer full
1-7 Automatic status back function Invalid Valid
1-8 Should not be changed (Should be set to on)

(2) ESC/POS mode

Switch
Function ON OFF
1-1 Command emulation Always OFF
1-2 Graphic Adjustment 203 DPI 180 DPI
1-3 Auto cutter Valid Invalid
1-4 Sensor adjustment Invalid Valid
1-5 Should not be changed (Should be set to on)
1-6 Handshaking conditions Offline or receive Receive buffer full
(conditions for BUSY) buffer full
1-7 Automatic status back function Invalid Valid
1-8 Should not be changed (Should be set to on)
DIP-SW 2
Switch
Function ON OFF
2-1
2-2 Always ON Should be set to on
2-3
2-4
ON
OFF
ON
OFF