Rev 0.01
TUP900 Series Specifications Manual 5-2
5-2 Static Electricity Tolerance (ESD)
Direct Electrical Discharge: Contact discharge ±6 kV (individual unit)
Air discharge ±8 kV (individual unit)
Indirect Discharge: ±6 kV (individual unit)
±4 kV (Checker connection)
Note) When using the optional power adapter (PS60L – 24A).
5-3 AC Line Noise Tolerance
±1200 V (individual unit)
±500 V (Checker connection)
Note) When using the optional power adapter (PS60L – 24A).
5-4 Vibrations, Falling Shocks
5-4-1 Vibration Test (When Packaged)
(1) Vibration Waveform: Sine wave
(2) Vibration Frequency: 10 to 55 to 10 Hz
(3) Total Amplitude: 1.54 mm (constant)
(4) Acceleration Speed: 0.3 to 9.3 G
(5) Direction: Three directions of X, Y and Z
(6) Time: 2 hours in each direction
(7) One-side Sweep Time: 5 minutes
5-4-2 Drop Test (When Packaged)
(1) No. of Drops: 10 times
(2) Height of Drop: 1 angle; 3 corners from 85cm; 6 surfaces from 1m
(3) Order of Drops: 1 angle 3 corners 6 surfaces
5-5 Dust
There is no affect on operation in a normal office environment.