State Industries 5 THRU 120 manual Element Chart And Connections, Control Circuit Fusing

Models: 5 THRU 120

1 4
Download 4 pages 543 b
Page 2
Image 2
Table 1. ELEMENT CHART AND CONNECTIONS

 

 

 

 

 

Table 1. ELEMENT CHART AND CONNECTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

State

 

 

 

 

Fits Tank

State

 

 

 

 

Fits Tank

 

Part

 

 

 

Element

Size

Part

 

 

 

Element

Size

 

Number

kW

Volts

Phase

Length

(Gals.)

Number

kW

Volts

Phase

Length

(Gals.)

 

5200

 

208

1 or 3

 

 

60001-4

 

208

1 or 3

 

 

60002-1

2

240

1 or 3

9.5"

5 thru 120

60002-6

9

240

1 or 3

15.5"

20 thru 120

60003-1

 

480

241.3 mm

 

60003-6

 

480§

393.7 mm

 

 

5200-1

 

208

1 or 3

 

 

60001-5

 

208

1 or 3

 

 

60002-2

3

240

1or 3

9.5"

5 thru 120

60002-7

10

240

1 or 3

15.5"

2 thru 120

 

60003-2

 

480

241.3 mm

 

60003-7

 

480

393.7 mm

 

60001-1

 

208

1 or 3

 

 

60001-7

 

208

1 or 3

 

 

60002-3

5

240

1 or 3

9.5"

5 thru 120

60002-9

12

240

1 or 3

15.0"

65 thru 120

60003-3

 

480

241.3 mm

 

60003-9

 

480§

381 mm

 

 

60001-2

 

208

1 or 3

 

 

60001-9

 

208

1 or 3

 

 

60002-4

6

240

1 or 3

12.0"

10 tru 120

60002-11

15

240

1 or 3

15.0"

65 thru 120

60003-4

 

480§

304 mm

 

60003-11

 

480§

381 mm

 

 

60001-3

 

208

1 or 3

 

 

60001-12

 

208

 

 

 

60002-5

7.5

240

1 or 3

14.5"

20 thru 120

60002-14

18

240

1 or 3

15.0"

65 thru 120

 

60003-5

 

480

368.3 mm

 

60003-14

 

480§

381 mm

 

§ Elements marked 277/480V. Element resistance wires operate at 277V 3Ø due to Y connection on element.

Table 2. CONTROL CIRCUIT FUSING

 

 

 

 

 

 

 

 

 

 

 

Voltage

120

208

220

240

277

380

415

480

575

600

 

 

 

 

 

 

 

 

 

 

 

Fuse Type

FNM

FNQ-R

FNQ-R

FNQ-R

FNQ-R

FNQ-R

FNQ-R

FNQ-R

FNQ-R

FNQ-R

VA

Secondary

 

 

 

 

Primary

 

 

 

 

 

0.6

1.25

 

 

0.8

0.6

 

 

0.4

0.4

50

(02005006)

(02006012)

NA

NA

(02006008)

(02006006)

NA

NA

(02006004)

(02006004)

 

2005-6

2006-6

 

 

2006-8

2006-6

 

 

2006-4

2006-4

 

1

1.5

1.5

1.5

1.25

0.8

0.8

0.6

0.6

0.6

75

(02005010)

(02006015)

(02006015)

(02006015)

(02006012)

(02006008)

(02006008)

(02006006)

(02006006)

(02006006)

 

2005-10

2006-15

2006-15

2006-15

2006-12

2006-8

2006-8

2006-6

2006-6

2006-6

 

1.25

2

2

2

1.5

1.25

1.25

0.8

0.8

0.8

100

(02005012)

(02006020)

(02006020)

(02006020)

(02006015)

(02006012)

(02006012)

(02006008)

(02006008)

(02006008)

 

2005-12

2006-20

2006-20

2006-20

2006-15

2006-12

2006-12

2006-8

2006-8

2006-8

 

 

 

 

 

 

 

 

 

 

 

Fuse Amp rating is shown in bold.

Seattle Part Numbers are shown in ( ).

PSD Part Numbers are shown underlined

Page 2
Image 2