State Industries Premium Heavy Duty warranty Recovery Rates, Optional Equipment & Construction

Models: Premium Heavy Duty

1 4
Download 4 pages 27.46 Kb
Page 2
Image 2
Optional Equipment & Construction

Premium Heavy Duty Electric Water Heater

Optional Equipment & Construction

Silicon Bronze Tank – Available for deionized water.

Stainless Steel Tank – Available for deionized water.

150 or 160 PSI Working Pressure – Available when required. Must be specified at time of order.

Handhole Cleanout – 4˝ x 6˝ size.

Combination Temperature/Pressure Gauge – Dial type combination gauge (shipped loose).

Control Options:

Low Water Cutoff – Probe type electric low water cutoff prevents energizing of elements in the event of low water condition.

Override Switches – A simple form of load control allows all or part of unit input to be controlled manually. Up to one override switch per contactor is available.

Indicating/Pilot Lights – For indicating element operation and/or switch closure. Up to one indicating light available for each switch and/or contactor is available.

Thermostat Step – The simplest form of modulation. Allows elements to be stepped on in groups or individually by specifying additional thermostats (up to 1 per contactor).

Control Options Continued:

Sequencer – Two or three step time delay sequencer provides for stepping of elements in groups or individually (maximum of 1 step per contactor).

Modulating Step – Solid state electronic control device that modulates input to match load through progressive sequencing of steps (up to 3 steps with maximum of 1 per contactor).

Time Clock – Seven day clock may be programmed for up to 14 on/off operations per week. Skip a day feature allows for weekend shutdown.

Immersion Auto Reset High Limit – Adjustable automatic reset type. Provides additional protection against high temperature conditions.

Safety Door Interlock – Prevents openings of control panel door when heater power supply is energized.

NOTE: Once door is open, the heater may be energized if necessary for service diagnosis.

Pressure Limit Switches – Both high and low pressure limit switches available.

Power Circuit Fusing Sub-divides internal circuitry with maximum of 60 amp fuses. Supplied as standard when required by NEC and UL.

Alarm Horn – Horns may be furnished to warn of any condition in the heater for which sensors have been specified.

RECOVERY RATES

Standard

Btu/

 

 

 

 

 

 

RECOVERY RATE IN GALLONS PER HOUR* - Temperature Rise ˚F

 

 

 

 

 

 

 

KW Input

Hour

30˚

 

40˚

 

50˚

 

60˚

 

70˚

 

80˚

 

90˚

 

100˚

 

110˚

 

120˚

 

130˚

 

140˚

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

10,239

41

 

31

 

24

 

20

 

17

 

15

 

13

 

12

 

11

 

10

 

10

 

9

6

20,478

82

 

62

 

49

 

41

 

35

 

31

 

27

 

25

 

22

 

21

 

19

 

18

9

30,717

123

 

92

 

74

 

62

 

53

 

46

 

41

 

37

 

34

 

31

 

28

 

26

12

40,956

164

 

123

 

98

 

82

 

70

 

61

 

55

 

49

 

45

 

41

 

38

 

35

15

51,195

205

 

154

 

123

 

102

 

88

 

77

 

68

 

61

 

56

 

51

 

47

 

44

18

61,434

246

 

184

 

148

 

123

 

105

 

92

 

82

 

74

 

67

 

62

 

57

 

53

24

81,912

328

 

246

 

197

 

164

 

140

 

123

 

109

 

98

 

90

 

82

 

76

 

70

30

102,390

410

 

308

 

246

 

205

 

176

 

154

 

137

 

123

 

112

 

103

 

95

 

88

36

122,868

492

 

369

 

295

 

246

 

211

 

184

 

164

 

148

 

134

 

123

 

113

 

105

45

153,585

615

 

461

 

369

 

307

 

263

 

230

 

205

 

184

 

168

 

154

 

142

 

132

54

184,302

738

 

554

 

443

 

359

 

316

 

277

 

246

 

221

 

201

 

185

 

170

 

158

60**

204,780

819

 

615

 

492

 

410

 

351

 

307

 

273

 

246

 

223

 

205

 

189

 

176

75**

255,975

1025

 

768

 

615

 

512

 

439

 

384

 

341

 

307

 

279

 

256

 

236

 

219

90**

307,170

1229

 

922

 

738

 

615

 

527

 

461

 

410

 

369

 

335

 

307

 

284

 

263

*Figured at 1 KW (3413 Btu) = 4.1 gallons at 100˚F temperature rise. **Available on 50 gallon models or larger.

To determine recovery rate per minute, divide recovery rate per hour by 60. NSF ratings may be obtained by multiplying above figures by 0.98.

COMMERCIAL 500 Lindahl Parkway, Ashland City, TN 37015 • www.stateind.com

The Expert’s Choice®

Page 2
Image 2
State Industries Premium Heavy Duty Recovery Rates, Optional Equipment & Construction, Handhole Cleanout - 4˝ x 6˝ size