S12Q-GOLD & S24Q-GOLD TROUBLESHOOTING GUIDE

SYSTEM STATUS

 

 

 

 

 

 

 

 

REMARKS

UV

AUDIBLE

UV LAMP

 

 

INTENSITY

ALARM

 

 

 

(LED)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GREEN

OFF

ON

Correct operating conditions unit is functioning properly.

 

 

 

 

 

 

 

 

System performance has declined due to stained or dirty

 

 

 

 

quartz sleeve and or sensor lens, or the lamp is beyond its

 

 

 

 

useful life.

YELLOW

OFF

ON

 

Clean sleeve and sensor probe lens or replace if required.

 

Replace lamp with manufacturer replacement.

 

 

 

 

 

 

 

 

Replace sensor with manufacturer replacement.

 

 

 

 

Always Wet Sensor Lens prior to inserting sensor.

 

 

 

 

check water quality (see page 2 for water parameters)

 

 

 

 

 

 

 

 

System failure is imminent due to stained or dirty quartz

 

 

 

 

sleeve or lamp is beyond useful life

FLASHING

INTERMIT-

ON

 

Clean sleeve and sensor probe lens or replace if required.

 

Replace lamp with manufacturer replacement.

RED

TENT

 

 

 

Replace sensor with manufacturer replacement.

 

 

 

 

 

 

 

 

Always Wet Sensor Lens prior to inserting sensor.

 

 

 

 

check water quality (see page 2 for water parameters)

 

 

 

 

 

 

 

 

UV Sensor has not detected enough UV Intensity to

 

 

 

 

adequately protect the water due to stained or dirty

 

 

 

 

quartz sleeve or the lamp is beyond its useful life.

RED

ON

ON

 

Clean sleeve and sensor probe lens or replace if required.

 

Replace lamp with manufacturer replacement.

 

 

 

 

 

 

 

 

Replace sensor with manufacturer replacement.

 

 

 

 

Always Wet Sensor Lens prior to inserting sensor.

 

 

 

 

check water quality (see page 2 for water parameters)

 

 

 

 

 

 

 

 

Ballast not functioning,

 

 

 

 

Reset Ballast by removing power for 30 seconds

 

 

 

 

 

then reapply.

RED

ON

OFF

 

Check wiring to ensure ballast is plugged into

 

 

circuit board.

 

 

 

 

 

 

 

 

 

Replace ballast with manufacturer replacement

 

 

 

Lamp is spent. Replace lamp with manufacturer

 

 

 

 

replacement

 

 

 

 

 

 

 

 

Defective UV sensor assembly. Replace sensor assembly with

GREEN

OFF

OFF

 

manufacturer replacement.

Calibration board improperly seated. Check board to ensure

 

 

 

 

proper engagement with main circuit board.

 

 

 

Defective sensor assembly.

 

 

 

 

 

 

8