SYSTEM STATUS |
|
|
| ||
|
|
|
|
| REMARKS |
UV | AUDIBLE | UV LAMP |
|
| |
INTENSITY | ALARM |
|
|
| |
(LED) |
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
GREEN | OFF | ON | • | Correct operating conditions unit is functioning properly. | |
|
|
|
|
| |
|
|
| • | System performance has declined due to stained or dirty | |
|
|
|
| quartz sleeve and or sensor lens, or the lamp is beyond its | |
|
|
|
| useful life. | |
YELLOW | OFF | ON |
| • | Clean sleeve and sensor probe lens or replace if required. |
| • | Replace lamp with manufacturer replacement. | |||
|
|
|
| ||
|
|
|
| • | Replace sensor with manufacturer replacement. |
|
|
|
| • | Always Wet Sensor Lens prior to inserting sensor. |
|
|
|
| • | check water quality (see page 2 for water parameters) |
|
|
|
|
| |
|
|
| • | System failure is imminent due to stained or dirty quartz | |
|
|
|
| sleeve or lamp is beyond useful life | |
FLASHING | INTERMIT- | ON |
| • | Clean sleeve and sensor probe lens or replace if required. |
| • | Replace lamp with manufacturer replacement. | |||
RED | TENT |
| |||
|
| • | Replace sensor with manufacturer replacement. | ||
|
|
|
| ||
|
|
|
| • | Always Wet Sensor Lens prior to inserting sensor. |
|
|
|
| • | check water quality (see page 2 for water parameters) |
|
|
|
|
| |
|
|
| • | UV Sensor has not detected enough UV Intensity to | |
|
|
|
| adequately protect the water due to stained or dirty | |
|
|
|
| quartz sleeve or the lamp is beyond its useful life. | |
RED | ON | ON |
| • | Clean sleeve and sensor probe lens or replace if required. |
| • | Replace lamp with manufacturer replacement. | |||
|
|
|
| ||
|
|
|
| • | Replace sensor with manufacturer replacement. |
|
|
|
| • | Always Wet Sensor Lens prior to inserting sensor. |
|
|
|
| • | check water quality (see page 2 for water parameters) |
|
|
|
|
| |
|
|
| • | Ballast not functioning, | |
|
|
|
| • | Reset Ballast by removing power for 30 seconds |
|
|
|
|
| then reapply. |
RED | ON | OFF |
| • | Check wiring to ensure ballast is plugged into |
|
| circuit board. | |||
|
|
|
|
| |
|
|
|
| • | Replace ballast with manufacturer replacement |
|
|
| • | Lamp is spent. Replace lamp with manufacturer | |
|
|
|
| replacement | |
|
|
|
|
| |
|
|
| • | Defective UV sensor assembly. Replace sensor assembly with | |
GREEN | OFF | OFF |
| manufacturer replacement. | |
• | Calibration board improperly seated. Check board to ensure | ||||
|
|
|
| proper engagement with main circuit board. | |
|
|
| • | Defective sensor assembly. | |
|
|
|
|
|
|
8