Setting the Process Air Temperature

Setting the Process Air Temperature

When setting the process air temperature, consult with the resin manufacture for the recommended drying temperature.

To change the process air temperature set point with the dryer running:

Press E5CN Operating ParametersAvailable E5CN ModesAdjustment Level to raise the set point to the temperature you want.

Press Manual backgroundManual backgroundManual background to lower the set point to the temperature you want.

Restoring the Process Air Temperature Controller (E5CN) to Factory Settings

If the preset parameters on the controller have been tampered with and it no longer properly controls temperature, you can restore the controllers to the factory setup. Call the Service

Department for detailed instructions.

E5CN Operating Parameters

The E5CN controller has several mode selections. Within each mode are numerous parameters that can be set.

The factory has set the security level to protect the critical parameters from being accidentally changed. Below is an explanation of the operating modes you will have access to and on the following page are the manufacturers’ default settings.

Available E5CN Modes

Operation Level

 

Indicator

 

Name

Description

 

 

 

 

 

 

 

 

Run/Stop Mode

When “RUN” is selected, the control is running.

 

 

 

(r-S)

When “STOP” is selected, the control is stopped.

 

 

 

 

When the control is stopped, the STOP display

 

 

 

 

lights. The default is set to “RUN.”

 

 

 

 

 

 

 

 

Alarm Value 1

This setting is used to indicate how many degrees

 

 

 

Mode (AL-1)

the process temperature will be allowed to exceed

 

 

 

(35°F)

the set point temperature. An alarm output will de-

 

 

 

energize the heaters and blower.

 

 

 

 

 

 

 

 

 

 

Adjustment Level

 

 

 

 

 

 

 

Indicator

 

Name

Description

 

 

 

 

 

 

 

 

Auto-Tune Mode

See Page 19 of Chapter 3 for instructions on how

 

 

 

(At)

to Auto-Tune your dryer.

 

 

 

 

Note: Although the controller is calibrated at

 

 

 

 

the factory, the manufacturer

 

 

 

 

recommends that the unit be Auto-

 

 

 

 

Tuned prior to dryer startup.

 

 

 

 

 

 

 

 

Temperature Input

This setting is used to offset an error between the

 

 

 

Shift Mode (TnS)

set point and the actual temperature. The entire

 

 

 

 

input range is shifted by a set figure

15, 30, & 60 cfm Compact Dryers

23