3-6 Installing the Remote-Mount Membrane Dryer (Optional)

The membrane drying kit can be mounted anywhere near the compressed air dryer. The kit is pre-assembled with a bracket that can be mounted to any flat surface with two screws. Use Figure 5 as a reference for this installation.

1.Remove the large particle filter, including the close nipple, from the inlet of the compressed air dryer.

2.Attach the large particle filter (including the close nipple) to the membrane drying kit.

Note: The membrane drying kit must have the large particle and the coalescing filters in place and functioning properly to ensure full drying capabilities of the membrane. Both filters must be checked and cleaned regularly.

3.Attach the 1/4” NPT elbow to the inlet of the compressed air dryer.

4.Run the 3/8” hose between the outlet of the membrane drying kit and the inlet of the compressed air dryer. Use thread sealant on all threaded connections.

Figure 5: Membrane Dryer Assembly

10 CFM Compressed Air Dryer

Chapter 3: Installation

18 of 30