Sterling manual SSK-30 4.2.3. Adjust the flap switch, Maintenance

Models: SSK-30

1 29
Download 29 pages 30.74 Kb
Page 25
Image 25
SSK-30

SSK-30

4.2.3. Adjust the flap switch

Remove the connecting plug “flap switch” from the connection housing of the hopper.

Connect an ohmmeter to PINS 2 and 3 of the connecting plug “flap switch”.

Release the nuts (A) of the flap switch (B) until the support can be displaced.

Open the outlet flap (C) so far that the front tip of the outlet flap is approx. 50 ± 2 mm (1.97 ± 0.18 in.) away from the sealing surface.

Displace the flap switch (B) until the contact of the magnet switch is closed.

Tighten the nuts (A) of the flap switch.

Check the adjustment:

In case of free hanging outlet flap (empty hopper loader) the contact of the magnet switch must be closed.

50 mm

C B A

Outlet flap

If the outlet flap cannot be properly adjusted, replace the flap switch or the outlet flap with magnet.

Install the hopper loader.

&

Part numbers

 

flap switch:

ID 33152

outlet flap with magnet:

ID 29699

 

 